Troubleshooting - Baumatic BBCSZ150GL User Manual

Single zone beverage centre
Table of Contents

Advertisement

Troubleshooting

IMPORTANT: If your beverage centre appears not to be
operating properly, before contacting Baumatic
Service Care, please refer to the checklist below.
PROBLEM
Appliance does not operate.
Appliance is not cold enough.
Turn-on and turn-off frequently.
The lighting does not work.
Too much vibration.
The appliance seems to make too
much noise
The door will not close properly.
Display flashes Error message "E1".
Display flashes Error message "E2".
POSSIBLE CAUSE / MEASURE
Not plugged in.
The appliance is turned off.
The circuit breaker has tripped or the fuse has blown.
Check the temperature control setting.
The door is opened too frequently.
The door is not closed completely.
The door gasket does not seal properly.
The room temperature is hotter than normal.
A large amount of contents has been added to the
Appliance.
The door is opened too frequently.
The door is not closed completely.
The temperature control is not set correctly.
The door gasket does not seal properly.
Not plugged in.
The circuit breaker has tripped or the fuse has blown.
The lighting is turned off.
Check to assure that the appliance is level.
The rattling noise may come from the flow of the
refrigerant, which is normal.
As each cycle ends, you may hear gurgling sounds
caused by the flow of refrigerant.
Contraction and expansion of the inside walls may
cause popping and crackling noises.
The appliance is not level.
The door is misaligned.
The appliance is not level.
The gasket is dirty.
The shelves are out of position.
Temperature sensor failure.
Defrost sensor (Coil Sensor) failure.