Parts and Accessories ............12 Mic Capsule Adjustments ........... 13 (EXPERT LEVEL ADJUSTMENT) ........13 Specifications ..............14 Wireless Designer Software ..........14 Firmware Update Instructions ..........14 Troubleshooting ..............15 Service and Repair .............. 17 Returning Units for Repair ..........17 LECTROSONICS, INC.
DSQD Receiver. The key is then ent while maintaining low distortion. It can be thought synced with the DHu via the IR port. The audio will of as two limiters in series, a fast attack and release be encrypted and can only be listened to if both DHu limiter followed by a slow attack and release limiter.
28 threads per inch and three contact rings Microphone Capsules: Lectrosonics offers two types of capsules. The HHC is the standard capsule and the HHVMC is the Variable Mic Capsule which includes adjustments for Bass, Midrange and Treble.
Digital Hand Held Transmitter Battery Installation Control Panel To insert batteries, close the eject lever and insert the Six membrane switches on the control panel are used upper contacts first (closest to the mic capsule). Polar- to set up the transmitter by navigating the menus on ity is marked on the label in the bottom of the battery the LCD and selecting the desired values.
The unit can also be turned off from any menu or and the LCD will return to the screen on the LCD by holding the power button in same screen or menu that while the status bar on the LCD is completed. was displayed previously. LECTROSONICS, INC.
The Venue and other receivers Phase from Lectrosonics offer a timer function to assist in this Phase Select option with arrow buttons Normal process.
Page 8
The frequency is shown on the transmit- Rolloff Normal ter LCD display in MHz and with a hexadecimal code that is used on most Lectrosonics receivers. Phase Inver t Frequency groups are also able to be received via IR (Inrared) port sync.
Page 9
KEY POLICY in the DSQD receiver). Set the matching KEY TYPE in the DHu and transfer KeyType the key from the receiver (SYNC KEY) to the DHu via WipeKey the IR ports. A confirmation message will display on SendKey the receiver display if the transfer is successful.
5) Once the audio gain has been set, the signal can be sent through the sound system for overall level adjustments, monitor settings, etc. To do this, the unit must be set to transmit (see Powering On and Off, and the Standby Mode). LECTROSONICS, INC.
Page 11
Digital Hand Held Transmitter Main Window Displays for Function Push To Talk is a momentary talk ProgSw switch. Audio is transmitted while The function of the Programmable Switch is displayed the button on the housing is held in the LCD Main Window. In the None and Power (opposite of cough) functions, no indication is displayed.
HHA Adapter by Ambient Recording Adapts Neumann KK104 and KK105 and Sennheiser cap- sules for the 5000 Series wire- less with Shure style threads to the DHu transmitter HHA is available from Ambient Recording dealers Visit: www.ambient.de LECTROSONICS, INC.
Digital Hand Held Transmitter Mic Capsule Adjustments Resonance tuned HHVMC capsule suspension (EXPERT LEVEL ADJUSTMENT) These adjustments significantly alter the gain and tonal quality of the microphone, and are to be used only in special circumstances. Attenuator EQ controls Caution: Always make the final decision about control (HHVMC only) sound quality with the windscreen in place.
Battery life: At 50 mW: 5 hours (Duracell Quantum); battery Firmware updates are made with a file downloaded status is transmitted to Lectrosonics receivers from the web site and the DBu connected via USB. Capsule Interface: 1.25” opening and 28 thread pitch...
4) Interference may be present. Turn transmitter off and observe the RF level indicator on the receiver. Change frequency if necessary. 5) With Lectrosonics HHC or HHVMC: return attenuator control back to default setting of “F” (see opposite page), then readjust audio gain per instructions on page 9.
Page 16
The normal condition of using this device is to keep the hand at least 20mm away from the base of the microphone. La condition normale d’utilisation de cet appareil est de garder la main à au moins 20 mm de la base du microphone. LECTROSONICS, INC.
There are no adjustments inside that will make a malfunctioning unit start working. LECTROSONICS’ Service Department is equipped and staffed to quickly repair your equipment. In-warranty repairs are made at no charge in accordance with the terms of the warranty. Out-of-warranty repairs are charged at a mod- est flat rate plus parts and shipping.
This warranty does not apply to used or demonstrator equipment. Should any defect develop, Lectrosonics, Inc. will, at our option, repair or replace any defective parts without charge for either parts or labor. If Lectrosonics, Inc. cannot correct the defect in your equipment, it will be replaced at no charge with a similar new item.
Need help?
Do you have a question about the DHu and is the answer not in the manual?
Questions and answers