Discharge Cone Assembly - 54 Inch Fan Only - Valco baby 954200 Manual

36, 50, 54 inch fiberglass fans and discharge cones
Hide thumbs Also See for 954200:
Table of Contents

Advertisement

DIsChARge CONe Assembly - 54 INCh fAN ONly

The assembled fan must be installed in the wall prior to mounting the cone to the fan.
It is recommended to fasten the top two straps first.
1. The cone is flexible and easy to install. Place cone sections on the ground with tabs positioned as shown in
Figure 26.
Figure 26
2. Assemble all 4 cone sections loosely using (2) ¼"-20 x 1" flange head screws (690343 (SS) or 690362 (ZP)) and ¼"-
20 flange nuts (MH8055 (SS) or 012792 (ZP)) at each joint. Do not tighten hardware. Note that the innermost slot
does not get any hardware at this point. When assembled properly all tab ends should be on the outside of the
cone. See Figure 26, 27, and detailed in 28 on the next page.
Figure 27
22