MCD 200 with MCD Remote Operator Option

This requires an MCD Serial Interface Module which clips onto the
side of the MCD 200. It is supplied with the MCD Remote Operator
when ordering Cat. No: 175G9004.
MCD200
Interface
Notes
• A single MCD Remote Operator and MCD Serial interface Module
is required for each MCD 200.
• No set-up or configuration is required for operation.
• If two Remote Operators are required, the RS485 Network side
of the first Remote Operator (terminals B6, B7, B8) must be con-
nected to the RS485 Starter side of the second Remote Operator
(terminals B1, B2, B3). The first Remote Operator is ordered using
Cat. No: 175G9004 and the second Remote Operator is ordered
using Cat. No: 175G3061.
• The Serial Interface Module is powered by the MCD 200. The
Remote Operator requires an external 18-30 VAC/DC auxiliary
supply.
• For more information on the MCD Remote Operator, refer to the
User Manual (MG.17.Ex.02)) located at www.danfoss.com/drives.
52 |
Danfoss Drives · DKDD.PB.551.A1.02
MCD
Serial
Module
-
69
GND
61
+
68
Cat. No: 175G9004
MCD Remote Operator
RS485
RS485
Starter
Network
-
B1
B6
GND
GND
B2
B7
+
B8
B3
-
+