Digisol DG-GO4300 Series User Manual

Digisol DG-GO4300 Series User Manual

Olt. web management

Advertisement

Quick Links

DG-GO4300 Series OLT

USER MANUAL

(WEB Management)

V2.0.1
19-04-2019
As our products undergo continuous development the specifications are subject to change
without prior notice.
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DG-GO4300 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Digisol DG-GO4300 Series

  • Page 1: User Manual

    DG-GO4300 Series OLT USER MANUAL (WEB Management) V2.0.1 19-04-2019 As our products undergo continuous development the specifications are subject to change without prior notice.
  • Page 2 COPYRIGHT Copyright 2019 by DIGISOL SYSTEMS LTD. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of this company.
  • Page 3: Table Of Contents

    DG-GO4300 Series OLT User Manual Contents Chapter 1 System Description ..................... 5 1.1Overview ..........................5 1.1.1 OLT Introduction ....................... 5 1.1.2 PC System Requirement..................... 6 1.2 Connection ........................... 6 Chapter 2 OLT Information ........................ 7 2.1 Login............................ 7 2.2 Device Information ....................... 7 Chapter 3 OLT Configuration ......................
  • Page 4 DG-GO4300 Series OLT User Manual 3.7.2 MAC Filter ........................19 3.7.3 IP/MAC Filter........................20 3.7.4 Effect Filter ........................20 3.8 IGMP ..........................21 3.8.1 Group Member .........................21 3.8.2 Global ..........................22 3.8.3 Port ..........................22 3.8.4 Port User VLAN .......................23 3.8.5 Port Mrouter ........................24 3.8.6 Mvlan ..........................25 3.8.7 Static Group........................25...
  • Page 5 DG-GO4300 Series OLT User Manual 4.2 ONU AutoFind ........................52 4.3 ONU AutoLearn ........................53 4.3.1 ONU AutoLearn .......................53 4.3.2 ONU AutoBind .........................54 4.4 ONU Upgrade ........................54 4.4.1 Upload Image ........................54 4.4.2 Manual Upgrade .......................55 4.4.3 Upgrade Status........................56 4.3.4 Auto Upgrade ........................57 4.5 Rogue ONU.........................57...
  • Page 6 DG-GO4300 Series OLT User Manual 5.4.2 Add profile ........................73 5.7 Bind Profile .........................74 Chapter 6 System Configuration ......................75 6.1 System Log .........................75 6.1.1 System Log........................75 6.1.2 Alarm ..........................75 6.1.3 Threshold Alarm .......................76 6.1.4 Syslog Server ........................77 6.2 Device Management ......................78 6.2.1 Firmware Upgrade ......................78...
  • Page 7: Chapter 1 System Description

    DG-GO4300 Series OLT User Manual Chapter 1 System Description Overview 1.1.1 OLT Introduction The Web management user manual is for the OLTs listed in Table 1-1. After you have completed installation, connection and commissioning of the equipment, you can start on configuring various services and functions for the equipment.
  • Page 8: Pc System Requirement

    DG-GO4300 Series OLT User Manual Management Mode SNMP, WEB, Telnet and CLI 1.1.2 PC System Requirement Table 1-2 PC System requirement Memory DISK Video Card Operating System 10GB 65000 color Windows2008 Frequency above Or above disk space resolving Windows XP...
  • Page 9: Chapter 2 Olt Information

    DG-GO4300 Series OLT User Manual Chapter 2 OLT Information 2.1 Login Follow the steps to login: 1. Conform “1.2 Connection” to connect; 2. The device default IP address is 192.168.8.200; 3. Open your web browser, type the device IP in address bar;...
  • Page 10: Chapter 3 Olt Configuration

    DG-GO4300 Series OLT User Manual Figure 2-2: Device Information Chapter 3 OLT Configuration This section is about the basic service of OLT configuration. 3.1 VLAN OLT equipment switch engine is fully compliant with the IEEE 802.1Q VLAN standard and has the following main features: ...
  • Page 11: Create Vlan

    DG-GO4300 Series OLT User Manual 3.1.1 Create VLAN OLT ConfigurationVLAN In this user interface, we can create new VLANs. Figure 3-1: Create New VLAN Page 9...
  • Page 12: Vlan Port

    DG-GO4300 Series OLT User Manual 3.1.2 VLAN Port OLT Configuration VLANVLAN Port. Figure 3-2: Add VLAN Port 3.1.3 QinQ/Translation OLT ConfigurationVLANQinQ/Translation In this user interface, VLAN QinQ and VLAN translation can be configured. VLAN QinQ and translation are effective for ingress.
  • Page 13: Uplink Port

    DG-GO4300 Series OLT User Manual Figure 3-3: QinQ/Translation Configuration 3.2 Uplink Port GE ports traffic statistics and basic configuration setting. 3.2.1 Information OLT ConfigurationUplink PortInformation This user interface displays traffic statistics of uplink ports. Page 11...
  • Page 14: Configuration

    DG-GO4300 Series OLT User Manual Figure3-4 : GE Traffic Statistics 3.2.2 Configuration OLT ConfigurationUplink PortInformation This user interface is used to configure port related functions and characteristic parameters of uplink port, such as port attributes, PVID, flow control, rate limit, storm inhibition, port isolation and so on.
  • Page 15: Pon

    DG-GO4300 Series OLT User Manual Illustrations of each parameter: Parameters Illustration GE port has two types, fiber SFP (GE1 to GE8) and Port ID copper (GE9 to GE16). Description Descriptions or remarks of port. Active or inactive status of port. It is "Enable" by Admin Status default.
  • Page 16: Configuration

    DG-GO4300 Series OLT User Manual Figure3-6: PON Information 3.3.2 Configuration OLT ConfigurationPONConfiguration This user interface is used to configure port status Page 14...
  • Page 17: Mac

    DG-GO4300 Series OLT User Manual Figure3-7: PON configuration 3.4 MAC In this section, you can check MAC address table of OLT, set MAC aging time and MAC limit of the ports. 3.4.1 MAC Table OLT ConfigurationMACMAC Table This table displays MAC addresses learned by OLT at PON and GE port.
  • Page 18: Configuration

    DG-GO4300 Series OLT User Manual Figure3-8: MAC Address Table 3.4.2 Configuration OLT ConfigurationMACConfiguration The default MAC aging time of OLT is 300s, user can change the value between 10~1000000s. Also, user can add the MAC to the OLT manually. Page 16...
  • Page 19: Lacp

    DG-GO4300 Series OLT User Manual Figure 3-9:MAC Configuration 3.5 LACP OLT ConfigurationLACPStatic LACP To assign and configure an uplink physical interface to an Ether Channel. When a link fails due to some reason, traffic will switch to another link automatically. The group range is from 1 to 4.Each group can add maximum of 4 ports.
  • Page 20: Qos

    DG-GO4300 Series OLT User Manual 3.6 QOS OLT ConfigurationQOS When bandwidth is not enough or there is congestion in the network, queue scheduling can make sure high priority data traffic passes through the device firstly. Traffic will map to queues according to their priorities and transmit in the queues.
  • Page 21: Ip Filter

    DG-GO4300 Series OLT User Manual This device supports the following types of ACL. 3.7.1 IP Filter The filter is based on the IP address, including the source IP address and destination IP address. OLT ConfigurationACLIP Filter Figure 3-12: IP Filter 3.7.2 MAC Filter...
  • Page 22: Ip/Mac Filter

    DG-GO4300 Series OLT User Manual Figure 3-13: MAC Filter 3.7.3 IP/MAC Filter OLT ConfigurationACLIP/MAC Filter Figure 3-14 IP/MAC Filter 3.7.4 Effect Filter Bind the access list to the ports. Each access list can be bound to several ports. OLT ConfigurationACLEffect Filter...
  • Page 23: Igmp

    DG-GO4300 Series OLT User Manual Figure 3-15: Bind Security Filter 3.8 IGMP 3.8.1 Group Member When there is a multicast group produced, the group will display in this table. OLT ConfigurationIGMPGroup Member Figure 3-16: Group Member Page 21...
  • Page 24: Global

    DG-GO4300 Series OLT User Manual 3.8.2 Global OLT Configuration IGMPGlobal. IGMP basic configuration mainly contains parameters of query packet. When IGMP status is checked, OLT works in IGMP snooping mode. IGMP snooping is the process of listening to Internet Group Management Protocol (IGMP) network traffic.
  • Page 25: Port User Vlan

    DG-GO4300 Series OLT User Manual Figure 3-18: IGMP Port 3.8.4 Port User VLAN OLT Configuration IGMPPort User VLAN This configuration is used to configure IGMP VLAN for OLT. Generally, PON ports should be configured and user VLAN and group VLAN are the same. If user VLAN and group VLAN are different, multicast VLAN will be translated.
  • Page 26: Port Mrouter

    DG-GO4300 Series OLT User Manual Figure 3-19: IGMP Port User VLAN 3.8.5 Port Mrouter OLT Configuration IGMPPort Mrouter Multicast router port is used to transmit IGMP signal messages. Generally, OLT uplink ports should be set as multicast router ports. Figure 3-20: IGMP Port Mroute...
  • Page 27: Mvlan

    DG-GO4300 Series OLT User Manual 3.8.6 Mvlan OLT Configuration IGMPMvlan This configuration is used to configure Mvlan and its mode. IGMP mode Unknown multicast Igmp packet Snooping drop trap –to -cpu Disable(transparent) forward forward Figure 3-21: IGMP MVLAN 3.8.7 Static Group OLT Configuration IGMPStatic Group...
  • Page 28: Rstp

    DG-GO4300 Series OLT User Manual Figure 3-22: IGMP Static Group 3.9 RSTP Spanning Tree Protocol is layer2 protocol, which is used to eliminate network loops by blocking network redundant links selectively. It has the feature of link backup as well.
  • Page 29: Global

    DG-GO4300 Series OLT User Manual Figure 3-23:RSTP Information 3.9.2 Global OLT ConfigurationRSTPGlobal This configuration is used to set RSTP parameters of the device, which contains RSTP switch priority, hello time, max age, forward delay and MAC address. Page 27...
  • Page 30: Port

    DG-GO4300 Series OLT User Manual Figure 3-24: RSTP Global Setup 3.9.3 Port OLT ConfigurationRSTPPort . This user interface is used to set port RSTP parameters which contain RSTP switch, priority, cost, edge port and point to point port. Page 28...
  • Page 31: Dhcp

    DG-GO4300 Series OLT User Manual Figure 3-25: RSTP Port Setting 3.10 DHCP OLT can support the following DHCP functions.  DHCP Server  DHCP Relay  DHCP Snooping Page 29...
  • Page 32: 1Dhcp Server

    DG-GO4300 Series OLT User Manual 3.10.1DHCP Server 3.10.1.1 DHCP Lease OLT ConfigurationDHCPDHCP ServerLease This table displays IP addresses assigned and their MAC addresses and lease time. Figure 3-26: DHCP Lease 3.10.1.2 DHCP Configuration OLT ConfigurationDHCPDHCP ServerConfiguration Sometimes the devices need dynamic IP addresses, but there is no special DHCP server in network.
  • Page 33: Dhcp Relay

    DG-GO4300 Series OLT User Manual Figure 3-27:DHCP Configuration 3.10.2 DHCP Relay 3.10.2.1 DHCP Relay Configuration OLT ConfigurationDHCPDHCP Relay Because the DHCP service exists in one broadcast domain, the server and the client are usually in the same network segment. DHCP relay can solve the issue that DHCP server and client do not exist in the same network segment.
  • Page 34: Dhcp Snooping

    DG-GO4300 Series OLT User Manual Figure 3-28:DHCP Relay Configuration 3.10.3 DHCP Snooping 3.10.3.1 DHCP Snooping Bind List OLT ConfigurationDHCPDHCP SnoopingBind List The static bind of the DHCP Snooping will be shown , Page 32...
  • Page 35 DG-GO4300 Series OLT User Manual Figure 3-29:DHCP Snooping Bind List 3.10.3.2 Global OLT ConfigurationDHCPDHCP SnoopingGlobal DHCP Snooping is used to prevent the DHCP message attacking and guarantee network to get a correct IP address. DHCP snooping global configuration mainly contains option 82 settings, DHCP traffic rate limit and snooping VLAN.
  • Page 36 DG-GO4300 Series OLT User Manual Figure 3-30:DHCP Snooping Global 3.10.3.3 Port OLT ConfigurationDHCPDHCP SnoopingPort This user interface is used to configure DHCP snooping parameters of ports which contain port type, option 82 parameters and rate limit. All the ports are untrust ports by default. Option82 parameters, “Option 82 Circuit ID”...
  • Page 37 DG-GO4300 Series OLT User Manual Figure 3-31:DHCP Snooping Port Setup 3.10.3.4 Static Bind OLT ConfigurationDHCPDHCP SnoopingStatic Bind DHCP snooping binding is useful when a host needs a fixed IP address assigned by DHCP server from the specific port. Page 35...
  • Page 38: Ip Route

    DG-GO4300 Series OLT User Manual Figure 3-32 DHCP Snooping Static Bind 3.11 IP Route 3.11.1 VLAN IP OLT ConfigurationIP RouteVLAN IP This configuration is used to configure IP address for VLAN. When the VLAN is added to a port, you can access the OLT by the IP address from the port.
  • Page 39: Arp Proxy

    DG-GO4300 Series OLT User Manual Figure 3-33:VLAN IP 3.11.2 ARP Proxy OLT ConfigurationIP RouteARP Proxy ARP Proxy is a technique by which a device on a given network answers the ARP queries for a network address that is not on that network. The ARP Proxy is aware of the location of the traffic's destination, and offers its own MAC address as final destination.
  • Page 40: Static Route

    DG-GO4300 Series OLT User Manual Figure 3-34: ARP proxy configuration 3.11.3 Static Route OLT ConfigurationIP RouteStatic Route Static route is a form of routing that a router uses for a manually-configured routing entry. In many cases, static routes are manually configured by a network administrator.
  • Page 41 DG-GO4300 Series OLT User Manual Figure 3-35: Static Route Page 39...
  • Page 42: Chapter 4 Onu Configuration

    DG-GO4300 Series OLT User Manual Chapter 4 ONU Configuration This chapter is about the ONU management by OLT. 4.1 ONU AuthList 4.1.1 ONU Status ONU ConfigurationONU AuthListONU Status Select PON port ID, all ONUs will be displayed in this interface.
  • Page 43: Onu List

    DG-GO4300 Series OLT User Manual 4.1.2 ONU List ONU ConfigurationONU AuthListONU List Select PON port ID, all ONUs will be displayed in this interface. Figure 4-2 ONU List 4.1.2.1 Delete ONU ConfigurationONU AuthListONU List Delete ONU which you selected, the ONU will be deleted and the registration shows...
  • Page 44 DG-GO4300 Series OLT User Manual Figure 4-3Delete ONU 4.1.2.2 Config ONU ConfigurationONU AuthListONU List Configure ONU parameter informationwhich you selected, Figure 4-4 Configure ONU Page 42...
  • Page 45 DG-GO4300 Series OLT User Manual Create a tcont ID and bind DBA templates Figure 4-5 Create Tcont Create a gemport ID and bind tcont ID Figure 4-6 Create gemport Create a service , Set the VLAN and VLAN mode and let it bind one gemport ID.
  • Page 46 DG-GO4300 Series OLT User Manual Figure 4-7 Create service Create a service port, Set the user VLAN and translate VLAN and let it bind one gemport ID. Figure 4-8 create service port Set the VLAN mode of the ONU’s port.
  • Page 47 DG-GO4300 Series OLT User Manual Figure 4-9 configure port VLAN mode Set the Multicast VLAN of ONU Figure 4-10 configure multicast VLAN Set the Multicast VLAN mode of ONU’s port Figure 4-11 Configure multicast VLAN mode Page 45...
  • Page 48 DG-GO4300 Series OLT User Manual Description for ONU Figure 4-12 ONU’s description Port Basic State of ONU Figure 4-13 ONU’s port state Create Iphost for ONU wan connection. Page 46...
  • Page 49 DG-GO4300 Series OLT User Manual Figure 4-14 Configure IPhost 4.1.2.3 Modify ONU ConfigurationONU AuthListONU List Modify SN or LOID of ONUwhich you selected, Figure 4-15 Modify ONU Registration mode Page 47...
  • Page 50 DG-GO4300 Series OLT User Manual 4.1.2.4 Optical Info ONU ConfigurationONU AuthListONU List Check the Optical Info of the ONU which you have selected. Page 48...
  • Page 51 DG-GO4300 Series OLT User Manual Figure 4-16 Optical info of ONU 4.1.2.5 Detail Info ONU ConfigurationONU AuthListONU List Check the Detail Info of ONU which you selected, Page 49...
  • Page 52 DG-GO4300 Series OLT User Manual Figure 4-17 Detail info of ONU Page 50...
  • Page 53: Onu Manual Add

    DG-GO4300 Series OLT User Manual 4.1.2.6 Reboot ONU ConfigurationONU AuthListONU List Reboot ONU which you have selected, Figure 4-18 reboot ONU 4.1.3 ONU Manual Add ONU ConfigurationONU AuthListONU Manual Add You can manually add an ONU to your chosen PON port. ONU will appear on the ONU list after you click on ‘Submit.’...
  • Page 54: Onu Autofind

    DG-GO4300 Series OLT User Manual Figure 4-19 ONU info 4.2 ONU AutoFind ConfigurationAutoFind After selecting PON port number, all ONUs which are authenticated, failed or not authenticated will be displayed in this interface. You can check the serial number of the ONUs.
  • Page 55: Onu Autolearn

    DG-GO4300 Series OLT User Manual Figure 4-21 Detail info 4.3 ONU AutoLearn 4.3.1 ONU AutoLearn ConfigurationAutoLearnONU AutoLearn ONU can be auto authenticated after enabling PON port automatic learning. Figure 4-22 Automatic learn Page 53...
  • Page 56: Onu Autobind

    DG-GO4300 Series OLT User Manual 4.3.2 ONU AutoBind ConfigurationAutoLearnONU AutoBind Input the Equipment ID and bind the template you need Note: you must build the template first Figure 4-23 Bind profile 4.4 ONU Upgrade ONU upgrade by OLT 4.4.1 Upload Image Upload ONU firmware image which you need, the image will upload to OLT’s RAM...
  • Page 57: Manual Upgrade

    DG-GO4300 Series OLT User Manual Figure 4-24 Upload image If the operation is successful, the following will appear Figure 4-25 Upload info 4.4.2 Manual Upgrade ONU ConfigurationONU UpgradeManual Upgrade Select ONU which you need and click commit button Page 55...
  • Page 58: Upgrade Status

    DG-GO4300 Series OLT User Manual Figure 4-26 Manual Upgrade 4.4.3 Upgrade Status ONU ConfigurationONU UpgradeUpgrade Status When ONU is upgrading, the list will be shown in this page. Figure 4-27 ONU Upgrade Status Page 56...
  • Page 59: Auto Upgrade

    DG-GO4300 Series OLT User Manual 4.3.4 Auto Upgrade ONU ConfigurationONU UpgradeAuto Upgrade The ONU firmware will be saved in the OLT’s RAM first. When the ONU comes online, it will auto upgrade the firmware. Figure 4-28 Auto Upgrade 4.5 Rogue ONU ONU ConfigurationRogue ONU...
  • Page 60 DG-GO4300 Series OLT User Manual Figure 4-29 Rogue ONU detect Page 58...
  • Page 61: Chapter 5 Profile Configuration

    DG-GO4300 Series OLT User Manual Chapter 5 Profile Configuration This chapter is about the ONU profile configuration. It is designed for batch ONU management by OLT. 5.1 ONU Profile The Onu profile is used for onu authorization, and each ONU must specify only one ONU profile when authorizated.
  • Page 62: Add Profile

    DG-GO4300 Series OLT User Manual 5.1.2 Add profile Create a new ONU profile what you need , Generally, ONU has two modes. SFU mode (only using bridge mode): Figure 5-2 Add SFU profile HGU mode (with the routing wan connection mode)
  • Page 63: Dba Profile

    DG-GO4300 Series OLT User Manual Figure 5-3 Add HGU profile 5.2 DBA Profile DBA is a bandwidth allocation strategy that changes uplink bandwidth assigned to each T-CONT in real time according to the instant service status of each ONU. There are five BW types supported and make sure that fix<=assure<=max.
  • Page 64: Add Profile

    DG-GO4300 Series OLT User Manual Figure 5-4 DBA profile list 5.1.2 Add profile Profile ConfigurationDBA Profile  Add profile Types:1,2,3,4,5,In general, we use type3 Relationships: Page 62...
  • Page 65: Traffic Profile

    DG-GO4300 Series OLT User Manual Figure 5-5 Add a DBA profile 5.3 Traffic Profile Traffic profile is used by Gemport to specify the upstream/downstream bandwidth. 5.3.1 Traffic profiles Profile ConfigurationTraffic Profile  Traffic Profiles The table displays Traffic profile list. We can also do some operation, such delete and modify.
  • Page 66: Add Profile

    DG-GO4300 Series OLT User Manual Figure 5-6 Traffic Profile list 5.2.2 Add profile Profile ConfigurationTraffic Profile  Add Profile Configure Gemport to specify the upstream/downstream bandwidth. SIR:Committed Information Rate PIR:Peak Information Rate CBS: Committed Burst Size PBS: Peak Burst Size...
  • Page 67: Line Profile

    DG-GO4300 Series OLT User Manual Figure 5-7 Add a traffic Profile 5.4 Line Profile Line profile is used to configure the ANI side services of ONU such as t-cont, gem-port, service-port and so on. 5.3.1 Line profile Profile ConfigurationLine Profile  Line Profile The table displays Line profile list.
  • Page 68: Add Profile

    DG-GO4300 Series OLT User Manual Figure 5-8 Line Profile list 5.3.2 Add profile Profile ConfigurationLine profileAdd profile Create a new line profile Figure 5-9 Add Line Profile Page 66...
  • Page 69 DG-GO4300 Series OLT User Manual Modify the line profile parameters Figure 5-10 Modify Line Profile Create a tcont ID and bind DBA templates Figure 5-11 Add Tcont Create a gemport ID and bind tcont ID Page 67...
  • Page 70 DG-GO4300 Series OLT User Manual Figure 5-12 Add Gemport Create a service , Set the VLAN and VLAN mode and let it bind one gemport ID. Figure 5-13 Add service Page 68...
  • Page 71 DG-GO4300 Series OLT User Manual Create a service port, Set the user VLAN and translate VLAN and let it bind one gemport ID. Figure 5-13 Add service port Set the Multicast VLAN of ONU Figure 5-14 configure multicast VLAN Page 69...
  • Page 72: Service Profile

    DG-GO4300 Series OLT User Manual 5.5 Service Profile Service profile is used to configure the UNI side services of ONU, such as Ethernet port, wifi, veip and so on. 5.3.1 Line profile Profile ConfigurationLine Profile  Line Profile The table displays service profile list. We can also do some operation, such as delete and modify.
  • Page 73 DG-GO4300 Series OLT User Manual Figure 5-16 Add Service profile Figure 5-17 Modify Service profile Set the VLAN mode of the ONU’s port. Figure 5-18 Port VLAN mode Page 71...
  • Page 74 DG-GO4300 Series OLT User Manual Set the Multicast VLAN mode of ONU’s port Figure 5-19 Port multicast VLAN mode Create Iphost for ONU wan connection. Figure 5-20 Add IPhost Page 72...
  • Page 75: Alarm Profile

    DG-GO4300 Series OLT User Manual 5.6 Alarm Profile Alarm profile is used to configure the parameters of ONU alarm. 5.4.1 Profile info Profile ConfigurationAlarm Profile Profile info Figure 5-21 Alarm Profile list 5.4.2 Add profile Profile ConfigurationAlarm Profile Add profile...
  • Page 76: Bind Profile

    DG-GO4300 Series OLT User Manual Figure 5-21 Create Alarm profile 5.7 Bind Profile After profile is configured, it is necessary to bind it to ONU. Profile ConfigurationBind Profile Figure 5-22 Bind profile Figure 5-23 select Profile Page 74...
  • Page 77: Chapter 6 System Configuration

    DG-GO4300 Series OLT User Manual Chapter 6 System Configuration This chapter is about the global management of OLT. 6.1 System Log 6.1.1 System Log System ConfigurationSystem Log Figure 6-1 System Log 6.1.2 Alarm System Configuration System Log Alarm. It contains all the alarms of OLT. User can choose the different alarms to "Print", "Record", "Trap"...
  • Page 78: Threshold Alarm

    DG-GO4300 Series OLT User Manual Figure 6-2 Alarm 6.1.3 Threshold Alarm Configure the temperature threshold, CPU-usage threshold and memory- usage threshold, PON optical threshold. Click System Configuration System Log Threshold Alarm. Page 76...
  • Page 79: Syslog Server

    DG-GO4300 Series OLT User Manual Figure 6-3 Threshold Alarm 6.1.4 Syslog Server Configure the server of OLT remote system logs. Click System ConfigurationSystem Log Syslog Server. Figure 6-4 Syslog Server Page 77...
  • Page 80: Device Management

    DG-GO4300 Series OLT User Manual 6.2 Device Management 6.2.1 Firmware Upgrade System ConfigurationDevice Management Firmware Upgrade. You can upgrade the OLT firmware by WEB, need to reboot the OLT after upgrade to take effect. Figure 6-5 Firmware Upgrade 6.2.2 Device Reboot System ConfigurationDevice Management Device Reboot...
  • Page 81: Config File

    DG-GO4300 Series OLT User Manual Figure 6-6 Device Reboot 6.2.3 Config File System ConfigurationDevice Management Config File, You can backup configuration, restore configuration, restore factory defaults and save configuration. Page 79...
  • Page 82: User Management

    DG-GO4300 Series OLT User Manual Figure 6-7 File Configuration 6.3 User Management System ConfigurationUser manage Two kinds of users have been defined, Normal and Admin. There are limitations to a normal user, and admin user has no limits . The default account member is Admin level.
  • Page 83: Snmp

    DG-GO4300 Series OLT User Manual Figure6-8: User Manage 6.4 SNMP 6.4.1 SNMP V1/V2 System Configuration  SNMP SNMP V1/V2 The OLT supports SNMP v1/v2, Page 81...
  • Page 84: Snmp V3

    DG-GO4300 Series OLT User Manual Figure6-9: SNMP V1/V2 6.4.2 SNMP V3 System Configuration  SNMP SNMP V3 The OLT supports SNMP V3. Page 82...
  • Page 85: Smnp V3 Trap

    DG-GO4300 Series OLT User Manual Figure6-10: SNMP V3 6.4.3 SMNP V3 Trap System Configuration  SNMP SNMP V3 Trap Configure or remove the Trap messages of the target host IP address. Figure 6-11: SNMP V3 Trap Page 83...
  • Page 86: Aux Ip

    DG-GO4300 Series OLT User Manual 6.5 AUX IP System Configuration  AUX IP AUX port is out band management port. The IP address is out band management IP, default IP address is 192.168.8.200. Figure 6-12: AUX IP 6.6 System Time 6.6.1 RTC...
  • Page 87: Ntp

    DG-GO4300 Series OLT User Manual Figure 6-13: RTC Configuration 6.6.2 NTP System Configuration  System TimeNTP Synchronize the time to the NTP server. Figure 6-14: NTP Configuration Page 85...
  • Page 88: Fan

    DG-GO4300 Series OLT User Manual 6.7 FAN System Configuration  FAN. The fans can be controlled to turn on/off, or turn on automatically. Figure 6-15: FAN Configuration 6.8 Mirror System Configuration  Mirror. Each monitor session can be set with one destination port and up to 8 source ports.
  • Page 89 DG-GO4300 Series OLT User Manual Figure 6-16: Mirror Page 87...
  • Page 90 DG-GO4300 Series OLT User Manual This product comes with standard one year warranty. For further details about warranty policy and Product Registration, please visit support section of www.digisol.com Page 88...

Table of Contents