Dg-gs4500se series mustang 4000 switch series 28 port layer 2 (1416 pages)
Summary of Contents for Digisol DG-GS1528HP/C
Page 1
DG-GS1528HP/C 24 PORT GIGABIT WEB MANAGED POE+ SWITCH WITH 2 GIGA COMBO + 2 GIGABIT SFP PORTS Web Management User Guide V1.0 2019-11-25 As our products undergo development the specifications are subject to change without prior notice...
Page 2
Please check with your local distributors for latest information. No part of this document can be copied or reproduced in any form without written consent from the company. Trademark DIGISOL is a trademark of Digisol Systems Ltd. All other trademarks are the property of the respective manufacturers.
DG-GS1528HP/C User Manual INDEX About guide..............................1 Terminology / Usage ............................1 Front panel ..............................2 Product Introduction ............................ 2 Rear panel ..............................2 Hardware installation ..........................3 First step: open a seal ............................ 3 Second step: switch installation........................3 Desktop or Shelf Installation ........................
DG-GS1528HP/C User Manual About guide This guide provides instructions to install the Switch. Note: The model you have purchased may appear slightly different from the illustrations shown in the document. Refer to the Product Instruction and Technical Specification sections for detailed information about your switch, its components, network connections, and technical specifications.
Thanks for purchasing the Web Managed PoE Switch products. The DG-GS1528HP/C is a Web Managed POE Switch, It provides 24 10/100/1000Mbps Auto-Negotiation RJ45 POE ports and 2 Combo (RJ45+SFP) +2 Gigabit SFP Ports . It supports the port's full line speed forwarding to ensure the stable transmission of data.
DG-GS1528HP/C User Manual Hardware installation This chapter provides unpacking and installation information for the Web Managed PoE switch. First step: open a seal Open the shipping carton and carefully unpack its contents. Please consult the packing list located in the User Manual to make sure all items are present and not damaged.
DG-GS1528HP/C User Manual Please be aware of following safety Instructions when installing: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer.
DG-GS1528HP/C User Manual Getting Started This chapter introduces the management interface of Web Managed PoE switch. Management Option The Web Managed PoE switch can be managed through any port on the device by using the Web-based management. Each switch must be assigned its own IP address, which is used for communication with Web-Based Management or a SNMP network manager.
DG-GS1528HP/C User Manual Login Web-based Management In order to login and configure the switch via an Ethernet connection, the PC must have an IP address in the same subnet as the switch. For example, if the switch has an IP address of 192.168.0.1, the PC should have an IP address of 192.168.0.x (where x is a number between 2~ 254), and a subnet mask of 255.255.255.0.
DG-GS1528HP/C User Manual Logon Dialog Box WEB page elements Shown in Figure 2, WEB page is mainly composed of three parts: title page, navigation tree page and main page Figure 2 Title page is Used to display the logo Main page is used to display the user from the navigation tree, select the page...
DG-GS1528HP/C User Manual The structure of Navigation tree Figure 3 shows the navigation tree organizational structure. Navigation tree is located in the lower left of each page, using the tree display nodes of the WEB page, users can easily find the page you want to manage the WEB. According to a different web page functionality can be divided into different groups, each including one or more pages.
DG-GS1528HP/C User Manual Error messages If the switch WEB server error occurred while processing user requests, it will display a dialog box in the corresponding error message. For example, Figure 4 shows an error message dialog box. Figure 4 5. Entry Field Some pages of the most left column in the table has an entry field, as shown in Figure 5, through the field can access different rows in the table.
DG-GS1528HP/C User Manual 6. Status Field Some pages of the most right column in the table there is a state field, as shown in Figure 6, the field displays the line status. Since all row state changes are processed in-house, so the status field is read-only. Once the line information of the entry filed into force, the line will automatically become the active state the status active.
Page 14
DG-GS1528HP/C User Manual WEB page introduction Switch WEB pages organized into groups, each including one or more of the WEB pages. The following are introduced one by one on each page. Login dialog Box Figure 7 WEB browsing session of the login page Figure 7 shows the login dialog box, the logon dialog box will be displayed while the user login the web page at the first time.
DG-GS1528HP/C User Manual Main Page Figure 8 shows the WEB main page of switch. This page will be displayed after the user logs in web pages Figure 8 Switch main page System Configuration: (1)Basic information page Figure 9 is the basic information of configuration page, users can configure the basic information for the switch.
Page 16
DG-GS1528HP/C User Manual Figure9 Basic information Page Serial port information page (2) Figure 10 is a serial port configuration page, the page displays serial baud rate and other related information. When the host through the serial port terminals (such as Windows, HyperTerminal) to the management of switches, serial console on the COM port configuration must be consistent with this page information.
Page 17
DG-GS1528HP/C User Manual (3)User management page Figure 11 is a user management page, the user can modify this switch anonymous user (admin) password, Telnet and the Web without opening a multi-user, they all use the same anonymous user's password. Passwords are case-sensitive and can be up to 16 characters.
Page 18
DG-GS1528HP/C User Manual Figure 12 Security management page (5)Configure the current page Figure 13 is the current configuration page. the user can view the current configuration of the switch on this page. Save key is to store the current system configuration in the configuration file. Because the storage operation requires erase&...
Page 19
DG-GS1528HP/C User Manual (6)Configuration page Figure 14 is profile configuration page. This page allows users to view the system's initial configuration. The initial configuration is actually the configuration file in the FLASH, when the configuration file does not exist in FLASH, the system starts using the default configuration.
Page 20
DG-GS1528HP/C User Manual Figure 15 File Upload Page (8)System reset page Figure 16 is system reset page, through this page users to restart the switch. When you click on Restart button, will pop up a dialog box that prompts the user to determine whether or restart the switch, If it is determined according to OK button, otherwise click Cancel button.
DG-GS1528HP/C User Manual Port Configuration (1)Port configuration / port -display page Figure 17 is the port configuration / port -display page. Users can enable or disable the port to the page, set the port speed, or View all ports of the basic information.
Page 22
DG-GS1528HP/C User Manual Figure 18 Port Statistics Page (3)Flow control page Figure 19 is the flow control page. Users can enable and disable each port’s send and receive flow control through this page. Flow control by sending the side of the drop-down on or off to open or close the sending side of flow control, flow control through the receiving side of the drop-down on or off to open or close the receiver-side flow control, while on and off also shows the port to send side and receiving-side flow control is turned on or off.
Page 23
DG-GS1528HP/C User Manual (4)Broadcast storm control page Figure 20 is the Broadcast Storm Control page. This page is used to do the suppression for configure port broadcast packets, multicast packets and DLF packet. From the Port drop-down bar select to configure ports. Through the on and off key to open and close the port broadcast suppression, multicast, DLF inhibition and suppression.
Page 24
DG-GS1528HP/C User Manual Figure 21 Port speed limit page (6)Port protection page Figure 22 is the Port protection page. This page is used to configure the port for the protection port. If the port is configured as a protected port, the ports cannot exchange the data with each other , protected port only with non-protected port for data exchange.
Page 25
DG-GS1528HP/C User Manual (7)Port Learning restrain page Figure 23 is the port learning restrain page. This page used to restrict the port can learn of the MAC address of the number, range is 0-8191. The default value is 8191, also is the maximum that the port is not configured the learning restrain.
Page 26
DG-GS1528HP/C User Manual Figure 24 Port Trunking configuration page (9)Port mirroring configuration page Figure 25 is the port mirroring configuration page. The page allows users to configure port mirroring. Port mirroring through the mirror port to monitor the data packets of being mirrored output port and the data packets of being mirrored input port.
DG-GS1528HP/C User Manual Figure25 Port mirroring configuration page MAC binding (1)MAC binding configuration page Figure 26 is the MAC binding configuration page. This page is used to achieve the port and MAC address binding. MAC entries on the page is used to enter the MAC address binding, VLAN ID entry is used to enter the MAC address...
DG-GS1528HP/C User Manual (2)MAC binding automatic conversion page Figure 27 is the MAC binding automatic conversion page. This page is used to achieve the port MAC address auto-binding. Fig Shows the hardware switch on the lay2 the exist port dynamic MAC address and affiliated VLAN.
Page 29
DG-GS1528HP/C User Manual Figure 28 the MAC filtering configuration page (2)MAC filtering automatic conversion page Figure 29 is the MAC filtering automatic conversion page. This page is used to achieve the port MAC address auto-binding. Shows the hardware switch on the lay2 the exist port dynamic MAC address and affiliated VLAN. Can choose one of the entries and convert it into static filtering configuration.
DG-GS1528HP/C User Manual VLAN Configuration (1)VLAN information page Figure 30 shows the current VLAN information page. This page is read-only page displays the current VLAN configuration information l, including the VID, state and port members. select VLAN from the drop-down VID, shows the port information of the Port VLAN members.
Page 31
DG-GS1528HP/C User Manual Figure 31 the static VLAN configuration page (3)VLAN port configuration page Figure 32 is a VLAN port configuration page, which is used to configure the VLAN port configuration and display results. This page mainly consists of eight parts: port, mode, all current VLAN, port-owned VLAN, key "default VLAN =>","...
DG-GS1528HP/C User Manual Figure 32 The VLAN port configuration page SNMP Configuration (1)SNMP share body configuration page Figure 33 is a shared body of SNMP configuration page that allows users to configure the switch common body's name and read and write access, A total of 8 entries can be configured By default, the switch there is a share name as public, the common body is read-only access.
Page 33
DG-GS1528HP/C User Manual Figure 33 a shared body of SNMP configuration page (2)TRAP target configuration page Figure 34 is the TRAP target configuration page that allows users to configure the workstation to receive TRAP messages as well as the IP address of TRAP protocol packets of some of the parameters.
DG-GS1528HP/C User Manual ACL Configuration (1)IP Standard ACL configuration page Figure 35 is the IP standard ACL configuration page. users can through this page to build ACL standard IP-rule base. User can select a ACL group number to create one or more rules. In a rule can match only the source IP address field (with mask).
Page 35
DG-GS1528HP/C User Manual (2)IP Extended ACL configuration page Figure 36 is the IP extended ACL configuration page. The extended IP group is an extension of the standard IP rules. Control the packet forwarding via source IP, Destination IP, IP protocol type and service port.
Page 36
DG-GS1528HP/C User Manual Figure 37 the IP Extended ACL configuration page (3)MAC IP ACL configuration page Figure 38 is the MAC IP ACL configuration page, IP MAC group can be the IP packet source and destination MAC address and source and destination IP address control.
Page 37
DG-GS1528HP/C User Manual (4)MAC ARP ACL configuration page Figure 39 is the MAC ARP ACL configuration page. ARP group can be the type of the operation of the ARP packet, the sender MAC and the sender IP control. Figure 39 the IP Extended ACL configuration page...
DG-GS1528HP/C User Manual (5)ACL information page Figure 40 is the ACL information page, which displays the current ACL rules configured in all the information. Figure 40 is the ACL information page QoS Configuration (1)QoS Apply Configuration Page Figure 41 is a QoS Apply configuration page.
DG-GS1528HP/C User Manual (2)QoS Schedule Configuration Page Figure 42 is a QoS Schedule configuration page. Figure 42 QoS Schedule configuration page 10. IP Basic Configuration (1)VLAN Interface Configuration Page Figure 43 is a VLAN interface configuration page, users can configure the VLAN interface through this page, delete VLAN interfaces, configure the interface IP address, remove the interface IP address, and view interface information.
Page 40
DG-GS1528HP/C User Manual Figure 43 VLAN interface configuration page Switch in the default have a VLAN1 interface, the interface cannot be deleted. One can only configure a VLAN interface. (2)ARP configuration and display page Figure 44 is the ARP configuration and display page, this page can display all of the information of the ARP table switch, while users can configure a static ARP entries on this page, delete ARP entries, and revised the dynamic ARP table entry to a static ARP table entry.
Page 41
DG-GS1528HP/C User Manual Figure 44 the ARP configuration and display page (3)Host Static Routing configuration page Figure 45 is the host static route configuration page, the user can through this page to add, delete static routing switch hosts. By default, the switch is not configured to host a static route, the user can configure the default route through this page, that is the purpose of address / subnet prefix is 0.0.0.0 / 0 routing...
DG-GS1528HP/C User Manual 11. Certification. Authorization. Accounting (AAA) configuration (1)Radius Configuration Page Figure 46 is the Radius configuration page, users can configure the Radius-related information, you can set information includes: 1. Be sure to set the Radius server's IP address before doing authentication and accounting in this field, 2.
Page 43
DG-GS1528HP/C User Manual 7. Server timeout timer, users typically do not need to modify this field. 8. Supplicant timeout timer, users typically do not need to modify this field. 9. Max Request number, users generally do not need to modify this field.
Page 44
DG-GS1528HP/C User Manual Figure 48 the 802.1x port configuration page Doing 802.1x authentication, port access, the default maximum host number is 100, the user can modify this field, the biggest support to the 100. (4) 802.1x user authentication information page Figure 49 is a 802.1x user authentication information page, the user can see through this page, under a certain port...
DG-GS1528HP/C User Manual 12. Spanning Tree Protocol configuration (1) MSTP global configuration page Figure 50 is the MSTP global configuration page, through which you can configure some MSTP related information, mainly including: Whether to enable MSTP. Configure the bridge priority. Devices with lower priority are more likely to be the root bridge.
Page 46
DG-GS1528HP/C User Manual (2) MSTP port configuration page Figure 51 is the MSTP global configuration page. Through this page, you can configure some MSTP related information, mainly including: Select the port to be configured. Configure a port as a portfast port to enable the port from the blocking state to the forwarding state, ...
DG-GS1528HP/C User Manual (3) MSTP configuration information page Figure 52 is the MSTP configuration information page, through which you can view some MSTP related information Figure 52 MSTP Configuration Information page 13. IGMP SNOOPING configuration (1) IGMP SNOOPING configuration page Figure 53 is the IGMP SNOOPING configuration page, through which you can start IGMP SNOOPING.
Page 48
DG-GS1528HP/C User Manual (2) IGMP SNOOPING information page Figure 54 is the IGMP SNOOPING information page, which allows users to view some information about IGMP SNOOPING. Figure 54 IGMP SNOOPING Information page...
DG-GS1528HP/C User Manual 14. GMRP configuration (1) GMRP Global Configuration Page Figure 55 shows the GMRP global configuration page. Users can enable GMRP through this page. Figure 55 GMRP Global Configuration Page (2) GMRP port configuration page Figure 56 shows the GMRP port configuration page. You can use this page to enable the GMRP port and view the port information.
DG-GS1528HP/C User Manual (3) GMRP state machine page Figure 57 is the GMRP state machine page. Users can view the GMRP state machine information through this page. Figure 57 is the GMRP state machine page 15. EAPS configuration (1) EAPS configuration page...
Page 51
DG-GS1528HP/C User Manual Figure 58 EAPS Configuration Page (2) EAPS information page Figure 59 is an EAPS information page, through which users can view some EAPS related information. Figure 59 EAPS information page...
DG-GS1528HP/C User Manual 17、RMON configuration (1) RMON statistics group configuration page Figure 60 shows the RMON statistics group configuration page. You can use this page to configure the RMON statistics group. Select a port from the drop-down list to view/configure the RMON statistics group configuration for this port.
Page 53
DG-GS1528HP/C User Manual Figure62 RMON history group configuration page (3) RMON alarm group configuration page Figure 62 shows the RMON alarm group configuration page. You can use this page to create or modify an RMON alarm group. Select a configured alarm group from the drop-down list to view/configure its information. Select New to create it.
Page 54
DG-GS1528HP/C User Manual (4) RMON event group configuration page Figure 63 is the RMON event group configuration page. Users can create or modify RMON event groups through this page. Select a configured event group from the drop-down list to view/configure its information. Select New to create it.
DG-GS1528HP/C User Manual 18、Cluster configuration (1) NDP configuration page Figure 64 shows the NDP configuration page. You can use this page to configure NDP. The configurable information includes: selecting the port, enabling the NDP function of the port, enabling the global NDP function, the interval for sending NDP packets, and the aging time of the NDP packets on the receiving device.
Page 56
DG-GS1528HP/C User Manual Figure 65 NTDP configuration page (3) Cluster Configuration Page Figure 66 is the cluster configuration page. Users can configure the cluster and view the cluster member table through this page. The information that can be set includes: enabling the cluster function, configuring the management VLAN, the address pool of the cluster, the interval for sending handshake packets, the effective retention time of the device, the name of the cluster, the way to join the cluster, and deleting the cluster.
DG-GS1528HP/C User Manual Figure 66Cluster Configuration Page 19 Log management (1) Log information page Figure 67 is the Log information page. Users can enable and view various log information through this page. Figure 67 Log Information Page...
DG-GS1528HP/C User Manual Critical: Output critical level information. Debugging: Outputs debug level information. Informational: Output information level debugging information. Warning: output warning level debugging information. ALL: output all log information 20、PoE port configuration (1)PoE port Configuration Page Figure 68 is the PoE port configuration / PoE-display page. Users can enable or disable the port's PoE ...
Need help?
Do you have a question about the DG-GS1528HP/C and is the answer not in the manual?
Questions and answers