Electrical Connections Of The Control Unit - Nice D-Pro Action Series Instructions And Warnings For Installation And Use

Table of Contents

Advertisement

9
8k2
8,2 kΩ
OSE
brown - 12V DC
green - Segnale
Signal
white - GND/0V
3.4 - Electrical connections of the control unit (Fig. 10)
CAUTION! – Before you proceed to make any electrical connections
make sure that the mains power supply is disconnected.
After attaching the control unit box and preparing the holes for routing the elec-
trical cables (see paragraph 2.3), make the electrical connections as follows:
01.
If this has not been done yet, first of all connect the power cable:
- for the NDCC2000 and NDCC2100 models, see paragraph 3.1
- for the NDCC2200 model, see paragraph 3.2
02.
Then, connect the power supply cable from the motor:
- Three-phase motor with mechanical limit switch (Fig. 11A)
- Three-phase motor with electronic limit switch (Fig. 12A)
- Three-phase motor with mechanical limit switch and brake (Fig. 11B)
- Three-phase motor with electronic limit switch and brake (Fig. 12B)
- Single-phase motor with mechanical limit switch and starting
capacitor (Fig. 13A)
- Single-phase motor with electronic limit switch and starting
capacitor (Fig. 13B)
03.
Lastly, connect the electrical cables of the various available accessories,
referring to Fig. 7 and paragraph 3.3.
Note – To facilitate connecting the cables, you can remove the terminals
from their positions.
10
10 – English
A
11
b
a
B
b
a
A
12
B

Hide quick links:

Advertisement