 0V to 10V DC input (14-bit mode only)
Conversion characteristic
(Note 1): In the analog input unit Ver.1.1 or earlier or the analog I/O unit, a digital conversion value equivalent to the
analog input of approx. 2 V is saved in the device (WX), for the channels to which no input is connected. The
analog input unit Ver.1.2 or later are equivalent to approx. 0V.
 0V to 5V DC input
Conversion characteristic
(Note 1): In the analog input unit Ver.1.1 or earlier or the analog I/O unit, a digital conversion value equivalent to the
analog input of approx. 2 V is saved in the device (WX), for the channels to which no input is connected. The
analog input unit Ver.1.2 or later are equivalent to approx. 0V.
4.5 I/O Conversion Characteristics
Correspondence table of A/D Conversion
values
Input voltage (V)
0.0
2.5
5.0
7.5
10.0
Processing if the range is exceeded
Input voltage (V)
0V or less (including
negative value)
10V or more
Correspondence table of A/D Conversion
values
Input voltage (V)
0.0
1.25
2.5
3.75
5.0
Processing if the range is exceeded
Input voltage (V)
0V or less (including
negative value)
5V or more
Digital value
14-bit
0
4000
8000
12000
16000
Digital value
14-bit
0
16000
Digital value
12-bit
14-bit
0
0
1000
4000
2000
8000
3000
12000
4000
16000
Digital value
12-bit
14-bit
0
0
4000
16000