Technical Data Coupling Nx; Technical Data Coupling Decoupling Models; Technical Data Coupling Nx5 Bs-3-480-Xx - EM TEST coupling NX5 bs-3-480-16 Manual

3-phase coupling decoupling network
Table of Contents

Advertisement

EM TEST
7.

Technical Data coupling NX

7.1.
Technical data coupling
7.1.1.

Technical data coupling NX5 bs-3-480-xx

Device
coupling NX5 bs-3-480-16
coupling NX5 bs-3-480-32
coupling NX5 bs-3-480-63
coupling NX5 bs-3-480-125
coupling NX5 bs-3-480-63.1
coupling NX5 bs-3-480-125.1
coupling NX5 bs-3-480-200.1
General data for family coupling NX5 bs-3-480-xx.y
Parameter
Impulse voltage Burst
Impulse voltage Surge
EUT
Phases
EUT supply voltage
Frequency
EUT DC current capacity
Output plug
AC / DC lines
Data lines Burst
Data lines Surge
Manual of operation
decoupling models
EUT nominal
Current
16 A
32 A
63 A
125 A
16, 32, 63 A
16, 32, 63, 125 A
16, 3 2, 63, 125, 200 A
Value
5.5 kV ± 10%
5.0 kV 2.5 kA ± 10%
3 phase: L1, L2, L3, N, PE
3 x 480 VAC
± 10%
50Hz, 60 Hz
DC current capacity see table in
Chapter 7.3.
DC current capability of coupling NX devices
16 A / 32 A
4 mm safety banana plug
63 A
6 mm safety banana plug (Multi Contact)
125 A
6 mm safety banana plug (Multi Contact)
200 A
10 mm safety banana plug (Multi Contact)
SHV coaxial
4 mm safety banana plug, double insulated
V 1.03
Inrush Max.
Weight [kg]
@230V
50 Hz
60 Hz
244 A
203 A
app. 30 kg
305 A
254 A
app. 45 kg
610 A
508 A
app. 100 kg
610 A
508 A
app. 200 kg
610 A
508 A
app. 100 kg
610 A
508 A
app. 180 kg
1220 A
1017 A
app. 200 kg
coupling NX
Dimension
19" 6HU
19" 6HU
19" rack, 25 HU
19" rack, 25 HU
19" rack, 34 HU
19" rack, 34 HU
19" rack, 34 HU
26 / 53