Technical Data Coupling Nx5 Bs-3-690-Xx.2 And Coupling Nx5 Bs-3-690-Xxx.3 - EM TEST coupling NX5 bs-3-480-16 Manual

3-phase coupling decoupling network
Table of Contents

Advertisement

EM TEST
7.1.3.

Technical data coupling NX5 bs-3-690-xx.2 and coupling NX5 bs-3-690-xxx.3

Device
coupling NX5 bs-3-690-16.2
coupling NX5 bs-3-690-32 .2
coupling NX5 bs-3-690-63.3
coupling NX5 bs-3-690-125.3
coupling NX5 bs-3-690-200.3
General data for family coupling NX5 bs-3-690-xxx.y
Parameter
Impulse voltage Burst
Impulse voltage Surge
EUT
Phases
EUT supply voltage
Frequency
EUT DC current capacity
Output plug
AC / DC lines
Data lines Burst
Data lines Surge
Manual of operation
EUT nominal
current [ac/dc]
16 A
32 A
16, 32, 63 A
16, 32, 63, 125 A
16, 3 2, 63, 125, 200 A
Value
5.5 kV ± 10%
5.0 kV 2.5 kA ± 10%
3 phase: L1, L2, L3, N, PE
3 x 690 VAC
± 10%
50Hz, 60 Hz
DC current capacity is same as for AC with separate DC input plugs
16 A / 32 A
4 mm safety banana plug
63 A
6 mm safety banana plug (Multi Contact)
125 A
6 mm safety banana plug (Multi Contact)
200 A
10 mm safety banana plug (Multi Contact)
SHV coaxial
4 mm safety banana plug, double insulated
V 1.03
Inrush Max.
Weight [kg]
@230V
50 Hz
60 Hz
244 A
203 A
app. 120 kg
305 A
254 A
app. 140 kg
610 A
508 A
app. 180 kg
610 A
508 A
app. 250 kg
1220 A
1017 A
app. 290 kg
DC: L1/DC+, N/DC-
coupling NX
Dimension
19" rack, 34 HU
19" rack, 34 HU
19" rack, 34 HU
19" rack, 34 HU
19" rack, 34 HU
28 / 53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents