Connecting Plate Coupling Nx5 Bs-3-480-125 Rack - EM TEST coupling NX5 bs-3-480-16 Manual

3-phase coupling decoupling network
Table of Contents

Advertisement

EM TEST
5.2.2.

Connecting plate coupling NX5 bs-3-480-125 Rack

1
EUT AC supply input 3 x 400 V / 100A
2
EUT supply input PF1 / N, PE;
3
EUT supply input PF2 / N, PE;
4
Sys Link out
5
Sync IN
6
Opto Link interface
1
EUT AC supply input 3 x 400 V / 63 A/ 100 A / 125 A
EUT mains supply via a CEE 100 A connector. This input EUT is internal not fused.
Connectors are rated with 63 A, 100 A or 125 A (color coded)
2
EUT supply input PF1, N, PE
EUT supply input of the compact NX5 generator to PF1, N and PE.
Plug: 4mm banana MC safety plug
EUT: 300 V / 16 A see manual compact NX5
3
EUT supply input PF2, N, PE
This input is not used.
4
Sys Link
Sys Link output to an external device
5
Sync IN
Input for external synchronization signal. (LOW / HIGH) max. 690 Vac. For more information refer to the
compact NX5 manual
6
Opto Link interface
Connector for external optical interface to the computer
7
Control Out 0-10Vdc
Output for control an external variable transformer
8
Ethernet interface
Ethernet interface to the remote computer
9
Auxiliary output
This BNC output is not used
10 System power Input and Fuse
Mains input connector to the Rack control devices, NX5 generator and coupling NX5 device.
100 V – 240 V ac
Input voltage:
Fuses:
10 A slow blow, 5 x 20 mm.
11 Emergency switch Slave
Emergency switch, slave output for control an external device
12 Emergency switch Master
Input for the safety circuit master switch
Manual of operation
Figure 5.4: coupling NX font view (model for 5kV/100 A / 16 A)
(300 V / 16 A)
not used
V 1.03
7
Control Out 0-10Vdc
8
Ethernet interface
9
Auxiliary output not used
10 System power input 100-240V
11 Emergency switch Slave
12 Emergency switch Master
coupling NX