Connecting Plate Coupling Nx5 Bs-3-690-200.3 Rack - EM TEST coupling NX5 bs-3-480-16 Manual

3-phase coupling decoupling network
Table of Contents

Advertisement

EM TEST
5.3.3.

Connecting plate coupling NX5 bs-3-690-200.3 Rack

1
EUT AC supply input 3 x 690 V / 200A
2
EUT DC supply input 1000 V / 200A
3
EUT supply input PF1 / N, PE;
4
EUT supply input PF2 / N, PE;
5
Sys Link IN / out
6
Sync IN (Low/High) max. 690 VAC
7
Opto-Link interface
1
EUT AC supply input 3 x 690 V / 200A
EUT mains supply via coded MC S16BV-N5 plugs. This input EUT is internal not fused.
5 coding possibilities are available (C1 – C5). These are achieved by varying the positioning of the guide
pins and grooves. The coding number is engraved on the connector beside the white marking.
Designation AC
Phase 1
Phase 2
Phase 3
Neutral
Ground
Important:
Only plugs and sockets with the same code number can be connected together.
2
EUT DC supply input 1000 V / 200A
EUT DC supply via coded MC S16BV-N5 plugs. This input EUT is internal not fused.
3
EUT supply input PF1, N, PE
EUT supply input of the compact NX5 generator to PF1, N and PE.
Plug: 4mm banana MC safety plug
EUT: 300 V / 16 A see manual compact NX5
4
EUT supply input PF2, N, PE
Same parameter as for PF1 (3).
5
Sys Link
System Link output and Input to external devices
6
Sync IN
Input for external synchronization signal. (LOW / HIGH) max. 690 Vac. For more information, refer to the
compact NX5 manual
7
Opto Link interface
Connector for external optical interface to the computer
8
Control Out 0-10Vdc
Output for control an external variable transformer
Manual of operation
Figure 5.4: coupling NX rear view
(300 V / 16 A)
not used
Symbol AC
Symbol DC
L1
DC +
L2
L3
N
DC-
PE
PE
8
Control Out 0-10VDC
9
Auxiliary not used
10 Ethernet interface
11 System power input 100-240V
12 Emergency switch Slave
13 Emergency switch Master
Code (MC)
V 1.03
coupling NX
C1
C2
C3
C4
C5
21 / 53