Rack With Built In Coupling Nx5-Bs-3-690-200.3; Front And Rear View Coupling Nx5-Bs-3-690-200.3 - EM TEST coupling NX5 bs-3-480-16 Manual

3-phase coupling decoupling network
Table of Contents

Advertisement

EM TEST
5.3.

Rack with built in Coupling NX5-bs-3-690-200.3

5.3.1.

Front and rear view coupling NX5-bs-3-690-200.3

1
Generator compact NX5
2
CDN coupling NX5 bs-3-690-200.x front
3
EUT Output 200 A
4
GND reference for table top EUT
5
Main switch
6
GND reference front floor standing EUT
7
Wheel
1
Generator compact NX5
Generator with control panel for the complete system
2
CDN couplingNX5 bs-3-690-200.x front
Front panel for of the CDN with output to the EUT. The LED indicates the impulse phenomenon that is actually used for
coupling. The coupling NX can handle the following Phenomenon: Burst and Surge
3
EUT output
Output plugs 200 A to
4
GND reference plate for table top EUT
The reference GND of table top must connected with a low inductive connection to this ground plate.
5
Main Switch
Main switches for the system supply (230V 50/50 Hz)
6/14 GND reference plate for floor standing equipment
On each front- and rear side is a GND reference plate for grounding the test system with the EUT ref GND plane and the
building GND. A low ohmic and inductive connection is required for this connection.
7
Wheel
Wheel with foot operated parking brake on front side wheels.
8/9 Screw for open the Rear Cover
For open the cover use a screw driver. Behind this are the cables and connections to the compact NX5 generator.
10 Current range selector switch
EUT current range selector (32A, 63 A, 125 A, 200 A). The current must be changed only in no load and no voltage condition.
12 EUT mains input for AC/DC
Input for 3 x 690 V and 1000 VDC wit Multi Contact plugs.
13 Control plugs
Panel for control and system mains connectors.
Manual of operation
L1/DC+, L2, L3, N/DC-, PE. HV-COM is for external surge data line CDN
8
Screw for open rear cover
9
Rear cover
10 Current range selector switch
11 Ventilation
12 EUT mains input AC / DC
13 Control plugs
14 GND reference rear floor standing EUT
V 1.03