Preparation

2.1

Requirements

Requirements
The following requirements must be fulfilled:
● You have an S7-300 station, consisting of:
● For operating the safety functions, you need:
● The following software packages and commissioning tools are correctly installed on your
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions
Getting Started, 10/2013, A5E02982990-04
– Power supply (PS), e.g., 6ES7307-1KA02-0AA0
– CPU 317TF-3PN/DP with Memory Card (8 MB or more),
6ES7317-7UL10-0AB0 V3.2/V4.1.5
– Digital input module, safety-related (F-DI) with bus connector,
for example, 6ES7326-1BK02-0AB0
– Digital output module, safety-related (F-DO) with bus connector,
for example, 6ES7326-2BF10-0AB0
– Safety protector, 6ES7195-7KF00-0XA0
– Digital input module (DI) with bus connector, for example, 6ES7321-1BH02-0AA0
– Digital output module (DO) with bus connector, for example, 6ES7322-1BH01-0AA0
– Two optional front connectors for the digital modules
– Emergency stop switch, dual channel - see the Configurator for pushbuttons and
SIRIUS 3SB3/3SF5 indicator lamp in the Internet
(http://www.siemens.com/industrymall)
– Key switch, dual channel - see the Configurator for pushbuttons and SIRIUS
3SB3/3SF5 indicator lamp in the Internet (http://www.siemens.com/industrymall)
– 2 hinge position switches, dual channel, to monitor the protected zone door - see the
Configurator for position switches in the Internet
(http://www.siemens.com/industrymall)
programming device with Ethernet interface:
– STEP 7 as of V5.5 SP2
– S7 Technology as of V4.2 SP3
– Distributed Safety as of V5.4 SP5 with F Configuration Pack as of V5.5 SP10