Configuration
4.11 Interconnecting the safety data block with SINAMICS parameters
Step
Activity
6
Open the "Binector connector converter" tab.
Click the button
Make sure that the p2051[10] parameter is interconnected in "Status word 4 sources".
Make the required interconnections according to "Interconnection of the safety data block" table, as shown in the
figure below.
The status word is then available at parameter r2089[3].
7
Select the Project > Save and Recompile All menu command to save and compile the entire technology project.
8
Switch to online mode by selecting the Project > Connect to selected target devices menu command.
9
In the project navigator, select SIMATIC 300(1) > Technology > S120_CU320_2_DP. To transfer the
configuration to the drive, select the Target system > Download > Download project to target system
menu command.
10
At the confirmation prompt for the download, select the "After loading, copy RAM to ROM" check box and click
"Yes".
68
to show the status word 4 bit by bit.
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions