Configuration

4.4 Configuring the F-DO signal module

4.4
Configuring the F-DO signal module
Use of the fail-safe output channels
Configure a fail-safe F-DO signal module. The table below shows which channels are used
and the meaning of the connected lights.
Table 4- 2
Channel
DO channel 0
DO channel 1
DO channel 2
DO channel 3
Note
You have to enter the password for the safety program to configure the fail-safe module.
The names and order of the parameters may differ from the following description if you are
using a different fail-safe module. You can find information on the parameters in the online
help.
Procedure
Step
Activity
1
In slot 7 of the hardware configuration, add an SM 326F DO10xDC24V/2A F-DO signal module
(6ES7 326-2BF10-0AB0).
2
Double-click the F-DO signal module.
The "Properties - FDO10xDC24V/2A" dialog box opens. Enter a password for the safety program, if
prompted.
3
Open the "Addresses" tab.
30
Use of the output channels
Use
Safety mode deactivated
Setup mode activated (safety door open and key switch on "Setup")
Emergency off active (emergency stop button is pressed or safety door
open without setup mode)
Acknowledgment required (at least one F-I/O has a fault requiring
acknowledgment or needs to be reintegrated)
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions
Getting Started, 10/2013, A5E02982990-04