4.3
Configuring the F-DI signal module
Use of the fail-safe input channels
Configure a fail-safe F-DI signal module. The following table shows which safety elements
need to be connected to the individual channels and how the channels need to be
configured.
Note
You must set a password to provide access permission for the safety program.
Table 4- 1
Channel
0 and 12
1 and 13
2 and 14
3
5
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions
Getting Started, 10/2013, A5E02982990-04
Configuration of the input channels, supply group 1Vs / 3Vs
Use
1. Safety door sensor,
dual channel
2. Safety door sensor,
dual channel
Emergency stop switch,
dual channel
Key switch for setup
mode, single-channel
Acknowledgment button,
single-channel
4.3 Configuring the F-DI signal module
Parameter
Evaluation of encoders
Type of encoder
interconnection
Evaluation of encoders
Type of encoder
interconnection
Evaluation of encoders
Type of encoder
interconnection
Evaluation of encoders
Type of encoder
interconnection
Evaluation of encoders
Type of encoder
interconnection
Configuration
Value
1oo2 evaluation
Dual channel equivalent
1oo2 evaluation
Dual channel equivalent
1oo2 evaluation
Dual channel equivalent
1oo1 evaluation
Single-channel
1oo1 evaluation
Single-channel
25