The drilling head will not move down or up.
The probe gets stuck when going up or down. 1) Dirt is stuck behind the ejector tip.
The drilling head will not stop when coming
up.
The probe ejects the sample onto the ground. 1) The chain in the drilling head
The drilling head has a lot of horizontal
play.
For testing the brake contact, the start switch and the foot switch just activate the ignition on the vehicle, but do not start the
motor. If all switches work, the rotation will start. It the rotation does not start, there is an error in one of the switches.
1) There is not enough power to the
tower (12 volts needed).
2) One of the three sensors is
broken or disconnected.
3) A fuse is blown.
4) The emergency stop is activated.
5) The hydraulic pressure of the
Honda motor is too low.
6) A wire for the computer is
disconnected.
7) The bottom sensor is broken.
8) The grey plug is not plugged in.
2) The probe is bent.
3) The chain is too loose and came
off the sprocket.
1) There is a broken top or middle
sensor.
2) The wire going to the sensor in the
drilling head came loose.
3) The wire going to the computer
Came loose.
came loose.
2) The probe is no longer aligned
correctly.
3) The sensor is not adjusted
correctly.
4) The sensor is not adjusted
correctly.
1) The screws holding the wearing
plates came loose.
2) The wearing plates are worn.
Wintex Agro, Vilhelmsborgvej 15, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
1) Recharge or change the battery.
2) Replace or change the sensor.
3) Set in a new fuse.
4) Deactivate the emergency stop.
5) Adjust the pressure.
6) Re-connect the wire.
7) Exchange the bottom sensor.
8) Plug in the grey plug.
1) Remove the dirt.
2) Set in a new probe.
3) Set the chain back on the sprocket and tighten
it.
1) Replace the broken sensor.
2) Tighten the wire.
3) Tighten the wire (I4 or I6).
1) Tighten the chain.
2) Re-align the probe to eject the soil into the
soil box.
3) Move the sensor in the drilling head closer to
the funnel or replace it.
4) Move the middle sensor in the tower closer to
the drilling head or replace it.
1) Tighten the screws.
2) Replace the wearing plates.