I/O modules
18
Overview
D
1
E
2
1
CDI
C
i
1
3
F
2
4
B
1
G
2
HR
on
3
A
WP
SIM
POWER
8
Position of the I/O modules in the terminal compartment
The terminal compartment contains up to four I/O modules, depending on the order code.
• Modules with four terminals can be in any of these slots.
• Modules with eight terminals can be in slot B or C.
The exact assignment of the modules to the slots is dependent on the device version. For a
detailed description refer to the Operating Instructions of the device in question.
The following restrictions apply when selecting the modules:
• The device may contain a maximum of four I/O modules.
• A maximum of two I/O modules with 8 terminals is possible.
Ordering feature 040: "Primary Output"
NMx8x -
xxxx
XX xx xx
...
040
Option
Number of I/O modules
A1
1
B1
1
E1
1
H1
1
Ordering feature 050: "Secondary IO Analogue"
NMx8x -
xxxx
xx XX xx
...
050
Option Number of I/O
Type of I/O module
modules
A1
1
1 x "Ex d/XP 4-20mA HART + RTD input" 1 x 8
A2
2
2 x "Ex d/XP 4-20mA HART + RTD input" 2 x 8
B1
1
1 x "Ex i/IS 4-20mA HART+ RTD input"
B2
2
2 x "Ex i/IS 4-20mA HART+ RTD input"
C2
2
1 x "Ex i/IS 4-20mA HART + RTD input"
1 x "Ex d/XP 4-20mA HART + RTD input"
X0
0
none
1
E
1
2
3
4
2
1
1
2
3
4
5
6
7
8
CDI
1
2
3
4
5
6
7
8
1
2
3
4
i
1
3
F
2
4
1
G
HR
2
on
WP
POWER
SIM
Type of I/O module
Modbus RS485
V1
4-20mA HART Ex d/XP
4-20mA HART Ex i/IS
Proservo NMS81
D
1
2
3
4
C
1
2
3
4
5
6
7
8
B
1
2
3
4
5
6
7
8
A
1
2
3
4
Number of terminals
Technical data
4
→ 19
4
→ 20
8
→ 21
8
→ 21
Number of terminals Technical data
→ 21
→ 21
1 x 8
→ 21
2 x 8
→ 21
2 x 8
→ 21
0
-
Endress+Hauser
A0027363
Need help?
Do you have a question about the Proservo NMS81 and is the answer not in the manual?
Questions and answers