Linear AccessKey Installation And Programming Instructions

Linear AccessKey Installation And Programming Instructions

Hide thumbs Also See for AccessKey:

Advertisement

Digital Keyless Entry System
Installation and Programming Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AccessKey and is the answer not in the manual?

Questions and answers

Summary of Contents for Linear AccessKey

  • Page 1 Digital Keyless Entry System Installation and Programming Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com...
  • Page 2: Table Of Contents

    Form “C” 1 Amp @ 24 Volts maximum ACCESSKEY OPERATION ..... . 10 Solid state outputs (Outputs #3 & #4) MANAGER’S ENTRY CODE LOG .
  • Page 3: Component Locations

    TACTILE REDUCE TERMINAL BLOCK J4 KEYPAD BEEPER SOUND POWER AND INPUTS KEYLOCK Figure 1. Component Locations WIRING DIAGRAM TYPICAL GATE INSTALLATION WIRING TYPICAL DOOR INSTALLATION WIRING ACCESSKEY ACCESSKEY N.O. N.O. COMMON COMMON RELAY #1 RELAY #1 TO ALARM N.C. N.C.
  • Page 4: Installation

    Use four security bolts and locking nuts to secure the keypad’s backplate to the pedestal (see Figure 3). Wall Mounting The AccessKey keypad can be mounted directly to a wall or flat surface. Use the appropriate fasteners to secure the keypad’s backplate to the mounting surface.
  • Page 5 2 WIRES FOR FOR DOOR (BEHIND GATE) REQUEST-TO-ENTER SENSE FIRE ACCESS KEYSWITCH ACCESSKEY KEYPAD 2 WIRES POWER 2 WIRES FROM ACCESSKEY 2 WIRES FROM OPERATOR TO TRIGGER GATE OPEN FOR ACCESSKEY POWER FROM ELECTRIC 2 WIRES POWER DOOR FOR DOOR SUPPLY STRIKE STRIKE Figure 5.
  • Page 6: Factory Defaults

    LED will blink. This number, i.e. 0001) do not need to be entered when indicates that the AccessKey is ready to accept the new programming a new entry code. The AccessKey will programming data. After the new data entry is complete, internally add any zeros to fill all digits determined the green LED will light while the data is being stored.
  • Page 7: Programming Options

    When programmed for DOOR SENSE, if an open condition PROGRAMMING OPTIONS on the input occurs before access is granted (with an entry There are several AccessKey programming options. For code or with the request-to-enter input) a FORCED most installations, the factory set default options are ENTRY output will occur.
  • Page 8 Default: 2 Seconds ! CAUTION: Performing a master reset will clear Sets the length of time Output #4 activates when triggered. the entire memory of the AccessKey and return Press: 2 4 Seconds all programmable options to the factory default values.
  • Page 9 (see Figure 9). These outputs can be used to activate indicators or sounders. See Figure 7 for wiring examples using the solid state outputs. ACCESSKEY POWER ELECTRONIC BEEPER 1K Ω 1K Ω...
  • Page 10: Accesskey Operation

    ACCESSKEY OPERATION  Users of the AccessKey have up to 40 seconds to key in their entry code.  Up to eight seconds are allowed between each keystroke.  All digits of the entry code must be entered. Example: If the code is 0042, the user must enter “0 0 4 2”.
  • Page 11: Manager's Entry Code Log

    MANAGER’S ENTRY CODE LOG NAME ADDRESS OR APARTMENT NUMBER ENTRY CODE RELAY NUMBER ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊ ◊...