Table 2. Spring Ranges, Part Numbers and Maximum and Minimum Pressures for the Manometric Sensing Devices (Types BMS1 and BMS2)
SPRING RANGE
4.0 to 14 in. w.c. / 10 to 35 mbar
10 to 33 in. w.c. / 25 to 83 mbar
18 in. w.c. to 2.0 psig / 45 mbar to 0.14 bar
1.0 to 3.5 psig / 70 mbar to 0.24 bar
1.7 to 5.6 psig / 0.12 to 0.39 bar
2 to 11 psig / 0.14 to 0.76 bar
4 to 19 psig / 0.28 to 1.3 bar
7 to 33 psig / 0.48 to 2.3 bar
15 to 75 psig / 1.0 to 5.2 bar
31 to 161 psig / 2.1 to 11.1 bar
59 to 235 psig / 4.1 to 16.2 bar
235 to 323 psig / 16.2 to 22.3 bar
323 to 588 psig / 22.3 to 40.5 bar
588 to 808 psig / 40.5 to 55.7 bar
808 to 1470 psig / 55.7 to 101 bar
81 to 323 psig / 5.60 to 22.3 bar
122 to 514 psig / 8.41 to 35.4 bar
257 to 1058 psig / 17.7 to 73.0 bar
1. Minimum suggested difference between slam-shut set pressure and normal operating pressure of the system.
2. Maximum difference between overpressure and underpressure when using one manometric device (Type BMS1) with tripping hook (see Figure 5). For underpressure and overpressure
points greater than this maximum number, use a second manometric device (Type BMS2) for underpressure protection.

Installation*

WARNING
!
Personal injury, equipment damage or
leakage due to escaping gas or bursting
of pressure-containing parts may result
if the slam-shut valve is installed where
its capabilities can be exceeded or where
conditions exceed any ratings of the adjacent
piping or piping connections. To avoid this,
install the slam-shut valve where service
conditions are within unit capabilities and
applicable codes, regulations or standards.
Additionally, physical damage to the
slam-shut valve could break the mechanism
box off the main valve, causing personal
injury and property damage due to escaping
gas. To avoid such injury or damage, install
the unit in a safe location.
Installation, operation and maintenance
procedures performed by unqualified
personnel may result in improper adjustment
and unsafe operation. Either condition may
result in equipment damage or personal
injury. Use qualified personnel when
installing, operating and maintaining the unit.
Clean out all pipelines before installation and check to be
sure the valve has not been damaged or collected foreign
material during shipment. Use suitable line gaskets and
good bolting practices with a flanged body. The Type OSE
must be installed in a horizontal position with the mechanism
box above the body (see Figure 2). The Types 627-OSX,
*For further instructions on Types 627, EZR, EZH and EZL, refer to the corresponding instruction manual of these products.
MANOMETRIC
SPRING
SPRING PART
SENSING
COLOR
NUMBER
DEVICE TYPE
Purple
FA113195X12
Orange
FA113196X12
Red
FA113197X12
Yellow
FA113198X12
162
Green
FA113199X12
Gray
FA113201X12
Brown
FA113202X12
Black
FA114139X12
Blue
FA113200X12
Brown
FA113202X12
71
Black
FA114139X12
Brown
FA113202X12
27
Black
FA114139X12
Brown
FA113202X12
17
Black
FA114139X12
Brown
FA113202X12
236
Black
FA114139X12
Gray
FA113201X12
315
MAXIMUM
MANOMETRIC
SENSING INLET
SENSING
PRESSURE,
DEVICE STYLE
psig / bar
4.0 in. w.c. / 10 mbar
5.6 in. w.c. / 14 mbar
74 / 5.1
7.2 in. w.c. / 18 mbar
Diaphragm
20 in. w.c. / 50 mbar
235 / 16.2
1470 / 101
Piston
1470 / 101
514 / 35.4
Bellows
1058 / 73.0
EZH-OSX, EZL-OSX and EZR-OSX are installed with
the mechanism box typically below the pipe. Type OS2
slam-shut device can also be installed in a pit that is subject
to flooding by venting the mechanism box above the
maximum possible flood level. When used below ground,
the vent must be relocated (piped) to keep the mechanism
box from collecting moisture and/or other foreign material.
Install obstruction-free tubing or piping into the 1/4 NPT vent
tapping. Provide protection on the relocated vent by installing
a screened vent cap into the end of the vent pipe.
Type OS2 can be used along with a token relief valve to
minimize unnecessary shutoff. The relief valve is set to
open before the Type OS2 slam-shut device activates.
This arrangement allows the relief valve to handle minor
overpressure problems such as gas thermal expansion or
seat leakage due to dirt moving through the system which
may move out of the regulator during the next operating
cycle. The slam-shut device does activate if the regulator
has a major malfunction with excessive gas flow that
exceeds the token relief capacity.
The manometric device requires an external sensing line
which should be tapped into a straight run of pipe 8 to
10 pipe diameters downstream or upstream of the slam-shut
device. If impossible to comply with this recommendation
due to the pipe arrangement, it may be better to position
the sensing line tap nearer the regulator or slam-shut outlet
rather than downstream of a block valve. Do not position
the tap near any elbow, swage or nipple which might cause
turbulence. It is recommended to install an isolation valve
and a vent valve on the sensing line, which can be useful for
tripping and verifications.
Type OS2
MAXIMUM DIFFERENCE
RECOMMENDED
BETWEEN
SETPOINT
OVERPRESSURE AND
DEADBAND,
UNDERPRESSURE,
psig / bar
(1)
psig / bar
(2)
1.6 in. w.c. / 4 mbar
4.0 in. w.c. / 10 mbar
2.0 in. w.c. / 5 mbar
10 in. w.c. / 25 mbar
20 in. w.c. / 50 mbar
24 in. w.c. / 60 mbar
2.2 / 0.15
5.1 / 0.35
1.16 / 80 mbar
8.7 / 0.60
2.47 / 0.17
16.0 / 1.1
5.08 / 0.35
36.3 / 2.5
10.2 / 0.70
79.8 / 5.5
23.2 / 1.6
145 / 10.0
43.5 / 3.0
Requires use
94.3 / 6.5
of Type BMS1
102 / 7.0
or BMS2
174 / 12.0
14.5 / 1.00
145 / 10.0
36.3 / 2.5
290 / 20.0
72.5 / 5.0
479 / 33.0