Gossen MetraWatt MAVOLOG PRO Operating Instructions Manual

Gossen MetraWatt MAVOLOG PRO Operating Instructions Manual

Power quality analyzer
Hide thumbs Also See for MAVOLOG PRO:

Advertisement

Short-form Operating Instructions
⏐PRO
MAVO
3-349-761-03
Power Quality Analyzer
2/8.18

Advertisement

Table of Contents
loading

Summary of Contents for Gossen MetraWatt MAVOLOG PRO

  • Page 1 Short-form Operating Instructions ⏐PRO MAVO 3-349-761-03 Power Quality Analyzer 2/8.18...
  • Page 2: Table Of Contents

    Contents Page Features ................2 Features • Evaluation of the electricity supply quality in compliance with Description ............... 2 EN 50160 with automatic report generation • Measurements of instantaneous values of more than 140 Application and Benefits ..........3 quantities including harmonics, flicker, power line signalling voltage, unbalance…...
  • Page 3: Application And Benefits

    Application and Benefits Compliance with Standards PRO power quality analyzer can be operated either The MAVO Measurements and reports of power (voltage) quality (PQ) indexes as a standalone monitoring device or within a network. It is desi- are only useful when can be compared with measurements and gned for the monitoring of power quality parameters.
  • Page 4: Voltage Quality

    Voltage Quality PQ reports PQ report is issued on a basis of chosen PQ parameters as well Voltage Quality is well defined term (sometimes also termed as information about a period of tracking and place of tracking Power Quality – PQ) and is covered with a selection of parame- (type of network).
  • Page 5: Measurements

    Measurements Online measurements Online measurements are available on display or can be moni- tored with setting and monitoring software MAVO-View. Readings on display are performed continuously with refresh time depen- dent on set average interval whereas rate of readings monitored with MAVO-View is fixed and refreshed approx.
  • Page 6 Meas. type Measurement 3-phase 3-phase 1-phase Comments 4-wire 3-wire Phase measurements Voltage 3 1ph 1-3_RMS AVG_RMS unbalance_neg_RMS unbalance_zero_RMS Current 3 1ph 1-3_RMS TOT_RMS AVG_RMS Power 3 1ph 1-3_RMS TOT_RMS 3 1ph reactive power can be calculated as a squared differ- 1-3_RMS ence between S and P or as sample delayed TOT_RMS...
  • Page 7 Meas. type Measurement 3-phase 3-phase 1-phase Comments 4-wire 3-wire Maximum demand measurements Maximum demand 3 1ph MD_I MD_P import MD_P export MD_Q MD_Q MD_S Min and max measurements Min and max 3 1ph 1-3_RMS_MIN 3 1ph 1-3_RMS_MAX 1-3_RMS_MIN 1-3_RMS_MAX 3 1ph 1-3_RMS_MIN 3 1ph 1-3_RMS_MAX...
  • Page 8: Recorder

    Recorder A built-in recorder (8 MB) enables storing measurements, detected alarms and PQ reports with details. It supports record- ing of up to 128 different quantities in 4 configurable partitions. For each partition is possible to set storage interval and other recording parameters.
  • Page 9: Real Time Synchronisation

    Real Time Synchronisation Communication  PRO Power Quality Analyzer has a wide variety of commu- Synchronized real-time clock (RTC) is an essential part of any MAVO Class A analyzer for proper chronological determination of various nication possibilities to suit specific demands. It is equipped with ...
  • Page 10: Technical Data

    Technical Data 11.3 INPUT / OUTPUT modules  PRO Power Quality Analyzer is equipped with two main I/ MAVO 11.1 Measurement inputs O slots, two auxiliary I/O slots and special time-synchronisation module. The following I/O modules are available: Nominal frequency range 50, 60 Hz Measuring frequency range 16 ...
  • Page 11: Time Synchronisation Input

    Analogue output (AO) 11.4 Time synchronisation input Output range 0 … 20 mA Digital input GPS or IRIG-B TTL Accuracy 0.5% of range 1pps voltage level TTL level (+5V) Max. burden 150 Ω Time code telegram RS232 (GPS) DC level shif (IRIG-B) Linearization Linear, Quadratic AM analog input...
  • Page 12: Real Time Clock

    11.9 Real time clock 11.11 - setting and acquisition Software MAVO-View  PRO A built-in real time clock is also without external synchronization MAVO-View software is intended for supervision of MAVO very stable when device is connected to auxiliary power supply. and many other instruments on a PC.
  • Page 13: Connection

    Connection System / connection Terminal assignment 1b (1W1b) Single-phase connection 3b (1W3b) Three-phase, three-wire connection with balanced load 3u (2W3u) Three-phase, three-wire connection with unbalanced load. GMC-I Messtechnik GmbH...
  • Page 14 System / connection Terminal assignment 4b (1W4b) Three-phase, four wire connection with balanced load 4u (3W4) Three-phase, four wire connection with unbalanced load. With this connection, a neutral current can be measured with 4 current sensor. Note With all connection schemes, terminal 12 (PE) must ALWAYS be connected.
  • Page 15: Dimensional Drawing

    Dimensional Drawing Connection table Function Connection Comment CAT IV 300 V AC current CAT III 600 V 26/27 Measuring input: CAT IV 300 V AC voltage CAT III 600 V UN 1 Module 1/2 – (common) Inputs / outputs: Module 3/4 –...
  • Page 16: Data For Ordering

    Data For Ordering  PRO Power Quality Analyzer, all required When ordering MAVO 15.1 General ordering code specifications shall be stated in compliance with the ordering The following specifications shall be stated: code. Additional information could be stated. M9200- 8× Relay output 8x Digital input (230 V AC/DC 8x Digital input (110 V...
  • Page 17: Example Of Ordering

    15.2 Example of ordering: Repair and Replacement Parts Service  PRO with a universal-HI supply is connected to a sec- Calibration Center and Rental Instrument Ser- MAVO ondary phase voltage up to 500 V L-N and 5 A secondary current vice on 50Hz network.
  • Page 18 Edited in Germany • Subject to change without notice • A pdf version is available on the Internet Phone +49 911 8602-111 GMC-I Messtechnik GmbH +49 911 8602-777 Südwestpark 15 E-Mail info@gossenmetrawatt.com 90449 Nürnberg Germany www.gossenmetrawatt.com •...

Table of Contents