CLEANING THE GENERATOR
Keep the generator clean to prevent improper operation or machine damage from dirt and debris. Inspect all
ventilation openings on the generator. These openings must be kept clean and unobstructed.
If the generator becomes dirty, use a damp cloth to wipe exterior surfaces. Use a soft bristle brush to loosen
dirt and oil and use a vacuum to pick up loose dirt. Use low pressure air (not to exceed 25 PSI) to blow
away dirt.
WARNING:
hose. Water can get inside the working parts of the generator and cause corrosion or a short circuit.
CHECKING/ADDING OIL
Check the oil level before each use and every 8 hours of operation (refer to Fig. 15).
The oil capacity of the generator engine is 11.8 fl. ounces. Add oil when the oil level is low. For proper
type and weight of oil refer to "ADD OIL" portion of the "GENERATOR PREPARATION" section. This is a criti-
cal step for proper engine starting. The generator is equipped with an automatic shutoff to protect it from
running on low oil.
To check the oil level and add oil:
1. Make sure the generator is on a level surface. Do not tilt the generator, as oil will flow into engine areas
and cause damage. Keep generator level!
2. Using a coin, turn the oil access cover screw 1/4 turn clockwise, then
remove the access cover from the service panel. Clean around the oil fill.
Remove the dipstick and wipe the it with a clean rag.
3. Insert the dipstick into the oil fill opening without screwing in. Re-
move the dipstick to check the oil mark (Fig. 16). Add oil if the oil mark
covers less than one half of the dipstick.
4. Using a funnel or appropriate dispenser, slowly add more oil. Repeat
step 2 until the oil mark reaches the top of the dipstick (you can see oil
coming up the threads of the oil fill). Do not over fill.
5. Reinstall dipstick and wipe clean any spilled oil with a rag. Reinstall
the oil access cover.
TIP:
Your WEN generator is compatible with the WEN 55201 Magnetic Oil Dipstick (not included), avail-
able for purchase at wenproducts.com. The dipstick's industrial-strength magnetic tip will collect metal
shavings from your generator's oil tank to help preserve the engine and extend your generator's lifespan.