Pressurized oil drain 24-gallon 90-liter
Hide thumbs Also See for A Series:

Advertisement

ASSEMBLY
1. Fig. 1. Insert handle into holding fixtures provided
on tank and secure it with screws. Place tool tray
A on bracket provided. Attach hose retainer B.
2. Fig. 2. Attach drain column C to drain basin and
tighten it with suitable wrench.
3. Fig. 3. Connect drain assembly to tank by tighten-
ing ring nut E with suitable wrench.
4. Fig. 4. Attach hose F with hose clamp provided.
5. Fig. 5. Close red handled ball valve G by turning it
clockwise.
OPERATING DRAIN
CAUTION
S Fig. 6. When draining fluids into the catch
basin, avoid automatic closing of the bleeder
vent on the funnel by leaving 1.5 to 2 in.
(4–5 cm.) clearance from upper limit funnel
extension.
S Fig. 7. The oil level gauge H located on the
side of the tank indicates the quantity of oil
drained. Never fill the tank over the maximum
level indicated by the gauge
Assembly and Operation
1. Fig. 6. To raise and lower funnel, loosen ring nut M
and hand tighten after reaching desired height.
EMPTYING DRAIN
CAUTION
Before emptying the tank, lift the funnel to its upper
limit so that the safety air bleeder vent is automati-
cally closed.
1. Fig. 7. Close red handled ball valve L.
2. Attach end of drain hose to suitable waste oil
container.
3. Connect 8 psi (0.5 bar, 50 kPa) shop air to valve D
and open ball valve G.
4. After fluids have been transferred from unit's tank
close ball valve G.
Note: Unit is equipped with pneumatic safety relief
valve that has been factory calibrated at 14 psi (1 bar,
100 kPa).
309042
5

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Oil ace 115599