3.5.3 Installing the magnet

Description
Ø Borehole diameter
d Depth
1 Distant washer
2 Distant washers
S Distant washer
OD x 5 x 13,3
M Magnet
W Corrugated washer
C Circlip

3.6 Safety screw to DIN 913

For MH and MT sensors, an M5x10 set screw to DIN 913 with flat point should be used. This safety screw is only required for blocking the sensor
housing in axial direction and needs to butt only against the groove, i.e. the screw may be tightened only with a max. torque of 0.5 Nm to prevent
damaging the sensor. The set screw should be inserted with a resolvable safety adhesive, e.g. Loctite blue.
4
4.5
Detail housing
All dimensions in mm
401 032
17.5
+0.1
17.4
+0.1
17.4 x 8 x 13.5
OD: 16.5 - 17.4
ID: 13.5 - 14
DIN 472 - 18 x 1
1
4.5
8.5
Detail safety screw
I
8
I
M Magnet
400 533
25.5
+ 0.1
13.0
+ 0.1
18.0
+ 0.1
25.4
+ 0.1
25.4 x 8 x 13.5
OD: 24.5 - 25.4
ID: 13.5 - 14
25 x 1
201 542-2
33
+ 0.1
33.0
+ 0.1
33.0 x 8 x 13.5
4 x M4
1 Nm
4 x M4
1 Nm