3.2 Chamfered edge for insertion

For correct and easy sensor mounting in the cylinder, a chamfered edge as shown in the drawing is required. To avoid damaging the O-ring during
installation, the radius at the transition from borehole to chamfered edge must be R0.6 - R1. Without this radius, there would be a sharp edge,
which could damage the O-ring.
B
3.3 Piston rod bore and depth
MH
N = Null zone
30 mm
S = Stroke range
D = Damping
acc. to actual data sheet and selected model no.
Ø Pressure pipe
MS
7 mm
MH
10 mm (7 mm)
MT
10 mm
3.4 CAD data, download
CAD models of all Temposonics
website (www.mtssensor.com). Go to our website, select Europe -> Support -> Login. Send a password request and you will be granted access to the
menu for engineering drawings, where you will find the 3-D model configurator for CAD model download.
N
MS
MT
22 mm
30 mm
Ø Piston rod
10 mm
13.5 mm (10 mm)
13.5 mm
MH, MS and MT sensor models are available for download in many commonly used data formats on the MTS
®
Detail B
S
Declarations in agreement with actual data sheet and selected model no.
The borehole depth is composed of measuring range (S), dampening (D)
and a clearance of 3 mm (depth = S + D + 3 mm).
Please pay attention:
• The position magnet shall not touch the pressure pipe.
• Do not exceed operating pressure.
I
6
I
D
> 3 mm
All dimensions in mm