Program Option
Audible/Visual
2E (1 & 2)
Switches
Unit Control
2F (3)
Loop Switches
30 - 37 (3)
Loop Switches
30 - 37 (4)
CL
Program Function
Entry/Exit
Pre-Alarm
Enable 4-minute
Power-Up
Delay
Allow Group
Shunting
Delay Before Dial This option programs the loops to have a delay after they are
Comments
If Digit Postition (1) is programmed for Entry Pre-Alarm, the
keypad will beep for the amount of time programmed for the Entry
Delay Time (CL 2D (3)). If Digit Position (2) is programmed for
Exit Pre-Alarm, the keypad will beep for the time programmed
into CL 2D (4), Exit Delay Time. The speed at which the keypad
beeps will increase during the last 10 seconds of the Delay time.
Alpha II keypads will display a bar graph in addition to the audible
tone.
Suppresses all trouble and alarm reports for a period of four
minutes after power is initially applied to the panel. This allows
the sensors, such as PIR's time to stabilize when initializing or
prevents powered devices, such as smoke detectors, from
sending alarms when first starting panel with a dead battery or no
battery connected.
This allows multiple loops to be shunted simultaneously with a
single keypad command. This is typically done on all interior
loops in a system.
triggered to allow the User time to shut down the system in the
event of an accidental triggering of the zone. The amount of time
is determined by the value programmed into CL 0B Digit Position
(1). The time delay may be between 10 and 150 seconds, in 10
second intervals.