The following is a summary of the questions most frequently asked of our Technical Support Department.
Question:
How do I program the panel with the LED keypad?
Answer:
To program with the LED keypad, enter the Command Location to be programmed, the Data to be pro-
grammed and the press the [#] key. (See also pages 6 - 7.)
For Example:
NOTE: The first digit of the User Code MUST be the same as the User Number.
Question:
How do I access Alpha Keypad Programming to enter Zone Labels?
Answer:
To begin Alpha Keypad Programming (you cannot program the LED keypad), enter [Installer Combination] [*]
[0] [1] [#]. Then scroll to the desired message location. (See also pages 7 - 8.)
Question:
How do I interpret a Trouble on the LED keypad? How do I clear a Trouble on the LED keypad?
Answer:
A number of conditions may cause the Trouble LED to light. See the chart below for additional information.
Trouble LED
Flash Slow
On
On
On
On
Question:
How do I enter hexadecimal numbers when using keypad programming?
Answer:
Hexadecimal values are entered through the use of the [*] key and one of the digits [0] - [5]. For additional
help with entering hexadecimal numbers, refer to page 7. The hexadecimal conversion chart is also found at
various locations throughout the programming section of the manual.
Question:
What is an "Interface error 1" and how do I correct the error?
Answer:
This error is caused by a problem with the Data line (Green wire) between the panel and the keypad. Check
the connection to ensure that the wire is not pinched or loose. Also try disconnecting all keypads from the
panel (one at a time), resetting the panel after each keypad is removed. Remember, to reset the panel press:
[Master Combination] [*] [6] [8] [#].
Question:
How do I reset Alarm Memory?
Answer:
To Clear Alarm Memory, press [*] [1] [#].
Question:
How do I address an Alpha Keypad for the first time?
Answer:
If you have an Alpha keypad that has never been addressed, when power is initially applied, the display will
read KEYPAD ADDRESS?. To enter the address, simply press a number between 0 and 7. Remove panel
power for 3 seconds and then re-apply power to reset the system. For additional information about Keypad
addressing, see page 5.
NOTE: If operating at or near the limit of AUX Power and Keypad Power, you may need to remove
Question:
Why do my loops fail to respond after changing the programming?
Answer:
In order for the panel to recognize the programming changes for the loops, either the loops have to be
tripped and restored or the panel must be reset ( [Master Combination] [*] [6] [8] [#] ).
Survey of Most Common Questions
To program User #2 with the ability to Arm only, No Reports and No Shunting; and
a PIN of 2543, enter the following keystrokes:
CL
Arm Type
[0][2]
[1]
Power LED
Zone LED's
On
On
Off
Flash Slow
On
power for up to 30 seconds in order for the system to reset properly.
PIN (w/EON)
[2][5][4][3][*][4]
Cause
Off
Watchdog
Flash Slow
Zone Trouble
Off
AC Failure
Off
Low Battery
Off
System Trouble (Bell Fuse or Comm Fail.)
22