Keypad Operation Command Summary - C&K systems SYSTEM 238 Installation Manual

Hide thumbs Also See for SYSTEM 238:
Table of Contents

Advertisement

The majority of the keypad commands apply equally to the LED and Alpha II keypads. Some keypad commands, however, apply
to the LCD keypad only.
The following Keypad Commands apply to both the LED and Alpha II keypads:
Function
Arm/Disarm
Bypass Zone (n)
Chime On/Off
Change Combo (via
Master Code)
Clear Alarm Memory
Exit Programming
Fire Alarm
Group Bypass and Arm
Group Bypass and Instant
Arm
Instant Arm
Keypad Activated RPS
Medical Alarm
Police/Panic Alarm
Reset Aux Power
Reset Panel
Test - Battery
Test - Bells
Test - Central Station
Test - Local Walk Test
NOTE: For additional information about Combination Command requirements, see page 24 and CL 09 (2).
The following Keypad Commands apply to the Alpha II keypad only:
Function
Error Tones Toggle On/Off
Audible Feedback Toggle
Backlight Toggle On/Off
Display Keypad Model
& Revision Number
Chime Toggle
Pre-warn Toggle On/Off
The following Keypad Commands are Installer Only Commands:
Function
Alpha Keypad Programming
Alpha Keypad Test
Kill/Revive Panel
Panel Programming

Keypad Operation Command Summary

Comments
Delays active
[n] is zone # 1 - 8; Combo may be required
Combo may be required
Must be done by User #1
Keypad activated
Arms system and all zones programmed for
group bypass, CL 30 - 3F, Digit Position (3),
are shunted simultaneously; Combo may be
required. (Also called Home Arming)
Same as Group Bypass (above) except system
is Instant Armed (Exit Delay operates normally,
upon expiration of Exit Delay, all delayed zones
are converted to Instant - No Entry Delay.
Combo may be required. (Also called
Instant/Home Arming)
Arms system and delayed zones are converted
to Instant (Exit Delay active, No Entry Delay);
Combo may be required
If enabled, CL 0B(3); Combo may be required
Keypad activated
Keypad activated
If resettable devices are connected to
Terminals 5 and 6 (also resets devices
connected to Loop 8 (e.g. 2-wire smoke
detectors)
Use after correcting Low Battery problem
Combo may be required
Combo may be required
Comments
Comments
Start Programming the Keypad
Start Programming the Panel
Keystroke Sequence
[Combination] [#]
[Combination] [Bypass] [n] [#]
[Combination] [*] [5] [#]
[Master Combo] [*] [0] [#]
[*] [1] [#]
[*] [#]
[F] (Hold for 3 seconds)
[Combination] [*] [4] [#]
[Combination] [*] [4] [7] [#] or
[Combination] [*] [7] [4] [#]
[Combination] [*] [7] [#]
[Combination] [*] [0] [2] [#]
[E] (Hold for 3 seconds)
[P] (Hold for 3 seconds)
[*] [6] [2] [#]
[Master Combination] [*] [6] [8] [#]
[*] [6] [4] [#]
[Combination] [*] [6] [3] [#]
[Combination] [*] [6] [1] [#]
[*] [6] [0] [#]
Keystroke Sequence
[*] [5] [4] [#]
[*] [5] [1] [#]
[*] [8] [#]
[*] [9] [#]
[*] [5] [3] [#]
[*] [5] [2] [#]
Keystroke Sequence
[Installer Combination] [*] [0] [1] [#]
[*] [6] [7] [#]
[Installer Combination] [*] [6] [9] [#]
[Installer Combination] [*] [0] [#]
21
SYSTEM 238 Installation Manual
[New Combo] [#] [New Combo] [#]

Advertisement

Table of Contents
loading