Input
Output

22-2-2. Operation System

MONITOR
ID No.

22-2-3. Monitor System

Moni/ID
Level LED
Power source
Monitor
INPUT
SIR-3400H / SIR-3032i / SIR-3032W
:
Connector
BNC x 32
Input format
Direct
Transmission format
Single-ended, Differential
Sensor power
supply
Input coupling
DC, AC (0.5 Hz)
± 0.1, ± 0.2, ± 0.5, ± 1, ± 2, ± 5, ± 10 Vpk
Input range
± 100 %
Input DC offset
(During coupling DC operation
only)
Input impedance
100 kZ
± 50 Vpk
Voltage-resistance
TEDS (IEEE1451.4) —
DIRECT input — Voltage input
IEPE input — Sensor input with built-in preliminary amplifier
:
BNC x 33 (Including 1 CH monitor in unit)
Connector
Transmission format
Single-ended
± 1, ± 2, ± 5, Variable (± 0.5 to ± 5) Vpk
Output level
50 Z
Output impedance
Adaptive load
Above 10 kZ
: Monitored channel selectable
: Unit ID number setting (1 to 4)
: Displays Monitored channel/Unit ID number
: Simultaneous indication for 1 to 32 channels, unidirectional indicator
: POWER
: MONITOR CH is displayed : LED on
Unit ID is displayed
: IEPE input
IEPE
Single-ended
24 V/4 mA
(Voltage drop of constant-current
circuit is 2 V)
AC (0.5 Hz)
1 % step
Support
: LED off
22. Specifications