4-1 Recording

This section describes recording of
external input signals.
Note
When two DNW-A25/A25P units are
combined, set both REMOTE/LOCAL
switches to LOCAL.
4-1-1 Preparations for
Recording
Perform the following procedure.
1
Connect the source signals.
2
Select video and audio signals
which you want to record.
Video: SDI or composite signal
(see "0 Source video signal
display" on page 2-20)
Audio: SDI or analog audio
signals for each channel (see
pages 2-23 and 2-24).
3
Make settings for reference video
signals (see page 2-10).
4
Make settings for timecode (see
page 2-12).
When using Betacam SP
cassettes
Set the SP TAPE switch to SX.
To adjust analog audio input
level
For recording analog audio signals,
you can adjust input level.
Set the AUDIO INPUT PRESET/
VARIABLE switch on the control
panel to VARIABLE. Turn the
AUDIO INPUT CH-1/CH-2 knobs,
monitoring the input levels indicated
by audio level meter.
4-1-2 Recording
Operation
Confirm that the cassette type display
on the sub LCD is "SX" and that the
REC INHI indicator on the control
panel is not lit.
Then, follow the procedure below.
REC
PREROLL
REC SEQ
EDIT
INHI
r
REW
SERVO
PLAY
F FWD
0
)
1
Press the REC/SEQ and PLAY
buttons at the same time.
Recording starts and the POWER
indicator turns to red.

Recording and Playback

METER
SP TAPE
1
CH-1/2
SX
SP PB ONLY
CH-3/4
STOP
STANDBY
2
p
(Continued)
4-1