[Pr. PF42 Function selection F-13 (*FOP13)]
Enable/disable temperature monitoring. For servo motors without a thermistor, temperature monitoring is disabled regardless
of the set value. When [AL. 46 Servo motor overheat] detection is enabled in [Pr. PF41 Parallel drive - Motor thermistor
setting], temperature monitoring is also enabled regardless of the setting of [Pr. PF42 Parallel drive - Temperature monitor
setting].
Setting digit
Explanation
_ _ _ x
_ _ _ x
(HEX)
(BIN)
5 PARAMETERS
40
Encoder master servo amplifier - Temperature monitor setting
0: Temperature monitoring enabled
1: Temperature monitoring disabled
Initial value
0h