Multidrop current
Set-up time
PROFIBUS PA
Manufacturer ID
17 (0x11)
Ident number
0x1559
Profile version
3.02
GSD file
Information and files under:
•
www.endress.com
GSD file version
•
www.profibus.org
Output values
Analog Input:
• Level linearized
• Distance
• Terminal voltage
• Electronic temperature
• Absolute echo amplitude
• Relative echo amplitude
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Digital Input:
• Digital output AD 1
• Digital output AD 2
• Switch output
Input values
Analog Output:
• Analog value from PLC (for sensor block external pressure to compensate gas phase
effects)
• Analog value from PLC to be indicated on the display
Digital Output:
• Extended diagnostic block
• Level limiter
• Sensor block measurement on
• Sensor block save history on
• Status output
Supported functions • Identification & Maintenance
Einfachste Geräteidentifizierung seitens des Leitsystems und des Typenschildes
• Automatic Ident Number Adoption
GSD compatibility mode with respect to the preceding product Micropilot M FMR2xx
• Physical Layer Diagnostics
Installation check of the PRFIBUS segment and the Micropilot FMR5x via the terminal
voltage and telegram surveillance.
• PROFIBUS Up-/Download
Up to 10 times faster writing and reading of parameters via PROFIBUS up-/download
• Condensed Status
Simple and self-explanatory diagnostic information by categorization of occurring
diagnostic messages.
FOUNDATION Fieldbus
Manufacturer ID
Device type
Device Revision
DD Revision
CFF Revision
Device Tester Version (ITK Version)
ITK Test Campaign Number
Link Master (LAS) capable
Micropilot FMR51, FMR52
4.0 mA
15 s
0x452B48
0x1028
0x01
Information and files can be found:
•
www.endress.com
•
www.fieldcommgroup.org
6.0.1
IT085300
yes
Endress+Hauser
Need help?