Summary of Contents for Uponor Comfort Port EU

  • Page 1 Uponor Comfort Port EU Technical Information...
  • Page 2: Table Of Contents

    Installation and Operation ............ 10 3.1 Design requirements ............... 10 Installation ................10 Operation ................. 12 Technical data and regulations ..........14 4.1 Standards and regulations ............14 Technical data ................15 Overview installation dimensions ........22 2 l Uponor Comfort Port EU l Technical Information...
  • Page 3: Prefabricated Cabinets

    Comfort Port, easy, fast and comfortable Comfort Port – made for the modern site Under floor heating Room thermostat Uponor Comfort Ports are ideally suited for use in multifamily houses or other residential buildings with high size of apartments due to enormous time and cost savings. Assembled according to customer specifications the Comfort Ports are delivered ready-to-install to the building site. Reduction of installation time, pre-wired actuators and control units, or marking of loops are only few of the advantages of preassembling in Uponor factory which avoids significantly installation errors on site. 9800 possible variances… Comfort Ports are available for all common mounting situations, and upon request, also with specific valves, heat meters and room control components from the Uponor Smatrix range. Operating principle ∂ ∂ Uponor Comfort Port EU l Technical Information l 3...
  • Page 4: Advantages

    Possible system constellations are so diverse that Uponor Comfort Ports are not produced off the shelf but exactly according to customer specifications. Configuration is easy on the PC with the Uponor Comfort Port Online Configurator. Based on the entered basic conditions and desired functions, the Comfort Port, which is needed for the respective construction project, is put together. The convenient query and order process ensures that no configuration parameters are forgotten. The delivery of the preassembled Uponor Comfort Ports is then carried out with the appropriate assignment marking in protective packaging suitable for the construction site, if desired directly to the construction site. The better, if you can save valuable working time by installing pre- fabricated modules. In the Uponor Comfort Ports, therefore, all the components required for the hydraulic connection and for connection to the room temperature control of a Uponor underfloor heating system are already integrated in the stable distribution box ready for connection. Depending on the configuration, even completely wired pump groups for connection to a heat generator without own flow temperature control are factory-installed in the Uponor Comfort Ports. Avoid assembly errors on the construction site Nobody is perfect. Just under time pressure happen on a construction site sometimes errors. Factory assembly and wiring of the control components in the Uponor Comfort Ports virtually eliminates the likelihood of something going wrong on the job site. All actuators are 4 l Uponor Comfort Port EU l Technical Information...
  • Page 5: Cost Comparison

    • Cabinet door made of sheet steel or plastic • Uponor 230V and all Smatrix single room controllers (wired or wireless) All mentioned components can be preassembled in 3 different cabinet types: • In-wall Cabinet with depth 80 mm • In-wall CAbinet with dept 110 mm • On-wall Cabinet with depth 140 mm The following examples show the 6 general variances of Comfort Ports. Uponor Comfort Port EU l Technical Information l 5...
  • Page 6 Horizontal w/o metering set Horizontal with metering set Uponor Vario S Manifold, 6 loops, with ball vale 3/4”, horizontal Uponor Vario S Manifold, 6 loops, with metering set 3/4”, horizontal connection. In wall cabinet. connection. On wall cabinet. Vertical with metering set and water counters Vertical with metering set Uponor Vario M manifold, 8 loops, with metering set 3/4”, vertical Uponor Vario S Manifold, 9 loops, with metering set 3/4”, vertical connection, with water meters. In wall cabinet. connection. In wall cabinet. 6 l Uponor Comfort Port EU l Technical Information...
  • Page 7 Vertical with PUSH 23 Uponor Vario S Manifold, 9 loops, with pump group PUSH 23, vertical connection. In wall cabinet. Vertical with dynamic balancing valve Uponor Vario S Manifold, 9 loops, balancing valve, vertical connection. In wall cabinet. Uponor Comfort Port EU l Technical Information l 7...
  • Page 8: Components

    Pump Group Uponor Fluvia T Push-23-B-W Constant flow temperature control station for use in combined systems with radiators and Uponor surface heating systems. Depending on the configuration, the Uponor Comfort ports can be equipped with the following components. Cabinets In-wall or on-wall cabinets made of sendzimir galvanized sheet steel, surface-mounted with 140 mm depth and flush-mounted with 80 and 110 mm depth.
  • Page 9: Configuration And Calculation

    Choose the Cabinet and the mounting variant of it. Result of your choice as tender text and production code needed for order the required Comfort Ports. The result of the selection is the tender text as well as a manufacturing code which describes the specific construction of each Comfort Port distribution cabinet. This code serves as identification for your order. Then the customized Comfort Port can be manufactured in a very short time: Delivery time “please country specific delivery time”. Uponor Comfort Port EU l Technical Information l 9...
  • Page 10: Installation And Operation

    7. The heating water used must comply with the requirements of VDI 2035. In the case of warranty claims, a water analysis is mandatory. 8. In order to ensure the hydraulic function of the individual heating circuits or the entire underfloor heating system, the individual heating circuits must be hydraulically regulated. 9. Prior to any work on the control module or the components connected to it, the control module must be switched to voltage-free according to the regulations. The comfort ports are already quipped with two spirit levels built into 10. For mounting and hydraulic and electrical connection of the the cabinets for easy leveling without additional tools for horizontal Uponor Comfort Ports, please refer to the enclosed installation and and vertical leveling. operating instructions. Damage caused to the Uponor Comfort Ports or the heating system or the building as a result of an infringement will void our warranty. 11. Properly instruct the user of the system in the operation of the system and hand over this technical information together with the inventory documents. If you have questions regarding the application or operation of Uponor products, please contact your Uponor contact person or contact our Technical Hotline directly. Technical Hotline Uponor: (put unit specific call number) 10 l Uponor Comfort Port EU l Technical Information...
  • Page 11 Connecting manifold feeder lines and the heating circuits If no heat meter is used, it may be necessary to replace the factory fitted plastic fitting with a metal fitting in continuous operation at high The primary-side supply and return connections are connected with G1 or G¾ transition fittings. Depending on the configuration, the temperatures. connection is either from below or from the side. For side connection, Please consider: by heat meter the cabinet dept needs to be the pre-punched side panel segments of the manifolds can simply min. 95 mm. Uponor Comfort Port EU l Technical Information l 11...
  • Page 12: Operation

    The Vario M manifold is set directly on the flow indicators acc. the the heating circuit distributor installed in the Comfort Ports. Detailed values from the underfloor heating planning documents (flow rate in information on filling and bleeding can be found in the enclosed ltr / min). installation and operating instructions of the Uponor heating manifold. Before commissioning, the Comfort Port and underfloor heating must be subjected to a leak test in accordance with EN 1264-4 and VOB DIN 18380. For related descriptions and forms, consult the Uponor Floor Heating System Technical Information. Hydraulic balancing of the heating circuits To ensure the required flow rate of the individual heating circuits according to the design calculation, the heating circuits must be hydraulically adjusted via the respective preset-able return control valves. Depending on whether a distributor with or without a flow indicator has been selected, the setting on the return control valve can be made according to the diagram (kv value) or after the flow has If required, the return control valve with the manual control cap can been read off. be completely shut off in accordance with the requirements of DIN EN 1264-4 without changing the default setting. Detailed information on hydraulic balancing can be found in the enclosed installation and operating instructions of the installed Uponor heating manifold. 12 l Uponor Comfort Port EU l Technical Information...
  • Page 13 Installation or connection of the Uponor Vario thermal actuators Uponor Vario 230V / 24V thermo drives are thermoelectric actuators for opening and closing valves on heating circuit distributors of surface heating systems. The thermo drives are connected to the flow valves via an adapter VA 10 with M30 x 1.5 thread. Adapter VA 10 During commissioning, the string valve is set to the particular with M30 x 1,5 differential pressure setpoint of the distributor installed in the Comfort Port. The drive is in the delivery state by the first-open function without Detailed information on hydraulic balancing can be found in the current geöff net. As a result, a heating operation in the shell enclosed installation and operating instructions of the string valve. phase is possible. During commissioning, the first open function is automatically unlocked by applying the operating voltage and the drive is ready for operation. Attention! Electric shock! Electrical connections to the 230 V power supply may only be used by authorized professionals be made. Uponor Comfort Port EU l Technical Information l 13...
  • Page 14: Technical Data And Regulations

    Water Ordinance or comparable country-specific regulations or A water analysis is recommended for each installation. In the case of standards takes place. warranty claims, a water analysis is mandatory. • The drinking cold water pipe is not together with to insulate warm It is essential that the heating circuits are regulated on the water side lines and if possible not to lay in the immediate vicinity of the so that a sufficient hydraulic function of the individual heating circuits same. or the entire underfloor heating system is guaranteed! 2. Electrical installations must be carried out in accordance with following regulations: commissioning and maintenance IEC 364 or CENELEC HD 384 or DIN VDE 0100 and IEC Report 446 or DIN VDE 0110 as well as EN 50178, EN 60204, EN 60335 / Part 1 and Part 51 or local regulations. Warning: Prior to any work on the controller or the components connected to it, switch off the controller according to the regulations. The outputs are also lost in the non-activated state mains voltage. 14 l Uponor Comfort Port EU l Technical Information...
  • Page 15: Technical Data

    16 – 17 1210 1250 1260 18 – 20 1510 1550 1543 18 – 20 1510 1550 1560 Depth: In-wall 80 – 120 or 110 – 150 mm, On-wall 140 mm Uponor Comfort Port EU l Technical Information l 15...
  • Page 16 14 – 16 1060 1100 1093 17 – 18 1210 1250 1243 19 – 20 1510 1550 1543 Depth: In-wall 80 – 120 or 110 – 150 mm, On-wall 140 mm 16 l Uponor Comfort Port EU l Technical Information...
  • Page 17 1100 1093 1210 1250 1243 17 – 20 1510 1550 1543 Depth: In-wall 95** – 120 or 110 – 150 mm, On-wall 140 mm ** by heat meter depth > 95mm Uponor Comfort Port EU l Technical Information l 17...
  • Page 18 13 – 15 1210 1250 1243 16 – 20 1510 1550 1543 Depth: In-wall 95** – 120 or 110 – 150 mm, On-wall 140 mm ** by heat meter depth > 95mm 18 l Uponor Comfort Port EU l Technical Information...
  • Page 19 10 – 12 1210 1250 1243 13 – 15 1510 1550 1543 Depth: In-wall 95** – 120 or 110 – 150 mm, On-wall 140 mm ** by heat meter depth > 95mm Uponor Comfort Port EU l Technical Information l 19...
  • Page 20 5 – 6 7 – 9 10 – 12 13 – 15 1060 1100 1093 1210 1250 1243 17 – 20 1510 1550 1543 Depth: In-wall 110 – 150 mm, On-wall 140 mm 20 l Uponor Comfort Port EU l Technical Information...
  • Page 21 17 – 18 1210 1250 1243 19 – 20 1510 1550 1543 Depth: In-wall 95** – 120 or 110 – 150 mm, On-wall 140 mm ** by heat meter depth > 95mm Uponor Comfort Port EU l Technical Information l 21...
  • Page 22: Overview Installation Dimensions

    690 + f 80 – 120 Uponor Comfort Port on wall Uponor Comfort Port on wall 140 Type [mm] 410/140 510/140 610/140 760/140 910/140 1060/140 1060 1210/140 1210 1510/140 1510 f = 0 – 2 22 l Uponor Comfort Port EU l Technical Information...
  • Page 23 Notes Uponor Comfort Port EU l Technical Information l 23...
  • Page 24 Uponor GmbH Industriestraße 56, D-97437 Hassfurt, Germany Uponor reserves the right to make changes, without prior notification, 1093008 – 10-2018 to the specification of incorporated components in line with its policy www.uponor.com Production: U ponor / JL / ME of continuous improvement and development.