Operating
medium
Time constant
t
0.632
Action
Capillary and
probe
Connecting
cable
water, oil, air, superheated steam
in water
≤ 45 sec
according to EN 60 730-1
Type 2BK =automatic action with micro switch-off in operation, with break
protection.
Materials
Capillary
standard
copper, Mat. Ref. 2.0090
1.5 mm dia.
on request
stainless steel,
Mat. Ref. 1.4571
1.5 mm dia.
Conductor cross-section 2.5 mm
6 Instrument description
in oil
≤ 60 sec
Probe
copper, Mat. Ref. 2.0090
brazed
stainless steel,
Mat. Ref. 1.4571
welded
2
max.
in air/ superheated
steam
≤ 120 sec