Removing The Reactors - Mitsubishi Electric PUHZ-HRP71VHA Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUHZ-HRP71VHA:
Table of Contents

Advertisement

OPERATING PROCEDURE
14. Removing the reactors (ACL1, ACL2, ACL3)
(1) Remove the service panel. (See Figure 1)
(2) Remove the top panel. (See Figure 1)
(3) Remove the 6 screws, that fix the front panel and remove
the front panel.
(4) Remove the 2 screws, screw
fix the separator, screw
9
from the bottom of the separator, and tilt the separator
to the side of the fan motor slightly. (See Photo 16)
(5) Disconnect the lead wires from the reactor and remove
the 4 screws, screw
reactor. (See photo 17 and 18.)
Note 1: The reactor is very heavy (4kg)!
Be careful when handling it.
Note 2: The reactor box is also removable.
Photo 17
Propeller
Reactors
OCH425F
8
9
and
(both 4 × 10), that
8
from the valve bed and screw
0
, that fix the reactor to remove the
Reactor box
Photo 16
Electrical
parts box
Reactor box
4-way
valve
Photo 18
Reactor box
132
PHOTOS
Electrical parts box
Screw 9
Separator
0
Screw
Screw8
Valve