Mitsubishi Electric PUHZ-HRP71VHA Service Manual page 93

Split-type, heat pump air conditioners
Hide thumbs Also See for PUHZ-HRP71VHA:
Table of Contents

Advertisement

(2) Functions are available when setting the unit number to 01-03 or AL (07 in case of wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 Set the
indoor unit number of Operating Procedure.
• When setting functions for a simultaneous twin indoor unit system, set the unit number to 01 to 02 for each indoor unit in
case of selecting different functions for each unit referring to 4 setting the indoor unit number of Operating Procedure.
• When setting the same functions for an entire simultaneous twin indoor unit system, set refrigerant address to AL (07 in
case of wireless remote controller) referring to 4 setting the indoor unit number of Operating Procedure.
Function
Filter sign
100h
2500h
No filter sign indicator
Quiet
Air flow
( Fan speed )
Standard
High ceiling
No.of air outlets
4 directions
3 directions
2 directions
Not supported
Optional high efficiency
Supported
filter
No vanes ( Vane No.3 setting : PLA only )
Vane setting
Vane No.1 setting
Vane No.2 setting
Energy saving air
Disabled
flow ( Heating mode )
Enabled
Not supported
Optional humidifier
( PLA only )
Supported
No.1 setting ( TH5: 24-28 )
Vane differential setting
No.2 setting ( Standard , TH5:28-32 )
in heating mode
( cold wind prevention )
No.3 setting ( TH5: 32-38 )
Swing
Not available Swing
Available
Set temperature in heating Available
mode ( 4 deg up ) * 1
Not available
Fan speed when the
Extra low
heating thermostat is OFF Stop
Set fan speed
Set fan speed
Fan speed when the
cooling thermostat is OFF Stop
Detection of abnormality of Available
the pipe temperature ( P8 ) Not available
*1 PKA-HAL/KAL : 2 deg up
Mode No.11
Setting No.
Settings
Vane No.3 setting
1
No Vanes
2
Vane No.1 setting
3
Vane No.2 setting
* Be careful of the smudge on ceiling.
PEAD-RP
JA(L)
Function
Filter sign
100h
2500h
No filter sign indicator
External static pressure 35/50/70/100/150Pa
External static pressure 35/50/70/100/150Pa
Set temperature in heating
Available
mode ( 4 deg up )
Not available
Fan speed during the
Extra low
heating thermo OFF
Stop
Set fan speed
Fan speed during the
Set fan speed
cooling thermo OFF
Stop
Detection of abnormality
Available
of the pipe temperature (P8)
Not available
OCH425F
Settings
}
PLA
Wave air flow
PLA-BA(2)(3)
Less smudging
( Downward position than the standard )
Standard
Less draft *
( Upward position than the standard )
Setting
Mode
Settings
No.
No.
1
07
2
3
Refer to the right table
08
Refer to the right table
10
1
24
2
1
25
2
3
1
27
2
1
28
2
93
Mode
Setting
4-Way
Ceiling
No.
No.
cassette
concealed
PEAD-JA(L)
PLA-BA(2)(3)
PEAD-EA(2)
PEA-GA
1
07
2
3
1
08
2
3
1
09
2
3
1
10
2
1
11
2
3
1
-
12
2
-
1
13
2
1
14
2
3
1
23
2
1
24
2
1
25
2
3
1
27
2
1
28
2
: Initial setting
External static
( Factory setting )
pressure
35Pa
50Pa
70Pa
100Pa
150Pa
: Initial setting ( Factory setting )
- : Not available
Wall mounted
PKA-FAL(2)
PKA-HAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Setting No.
Mode No. 08 Mode No. 10
2
1
1
3
1
2
2
2
2
3
PKA-KAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Initial setting
( Factory setting )