Mitsubishi Electric PUHZ-HRP71VHA Service Manual page 18

Split-type, heat pump air conditioners
Hide thumbs Also See for PUHZ-HRP71VHA:
Table of Contents

Advertisement

PUHZ-HRP100YHA2
[LEGEND]
SYMBOL
NAME
TB1
Terminal Block<Power Supply>
TB2
Terminal Block<Indoor/Outdoor >
MC
Motor for Compressor
MF1, MF2
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
SV
Solenoid Valve (Bypass Valve)
63H
High Pressure Switch
63L
Low Pressure Switch
63HS
High Pressure Sensor
TH3
Thermistor<Liquid>
TH4
Thermistor<Discharge>
TH6
Thermistor<Outdoor 2-Phase Pipe>
TH7
Thermistor<Ambient>
TH32
Thermistor<Suction>
TH33
Thermistor<Ref. check>
LEV-A, LEV-B, LEV-C
Electronic Expansion Valve
ACL1~ACL4
Reactor
RS
Rush Current Protect Resistor
CB1, CB2
Main Smoothing Capacitor
CK
Capacitor
TH33
C . B .
CNF1
1
MF1
(WHT)
1
7
MS
TH33
3 ~
( YLW )
CNF2
1
MF2
(WHT)
7
MS
3 ~
3
TRANS
1
2
CNDC
(PNK)
F2
F1
CNS
(WHT)
3
1
TB2
S1
S2
INDOOR
UNIT
S3
TB1
RED
L1
WHT
L2
POWER SUPPLY
3N~
BLK
400V 50Hz
L3
BLU
N
GRN/YLW
M-NET ADAPTER
TB7
Terminal Block<M-NET connection >
CN5
Connector<Transmission>
CND
Connector<Power Supply>
CN2M
Connector<M-NET communication>
SW1
Switch<Status of communication>
SW11
Switch<Address setting: 1s digit>
OCH425F
PUHZ-HRP125YHA2
SYMBOL
P.B.
Power Circuit Board
TB-U/V/W
Connection Terminal<U/V/W-Phase>
TB-L1/L2/L3
Connection Terminal<L1/L2/L3-Power Supply>
TB-P2
Connection Terminal
TB-C1
Connection Terminal
TB-N1
Connection Terminal
X52A
52C Relay
N.F.
Noise Filter Circuit Board
LI1/LI2/LI3/NI
Connection Terminal<L1/L2/L3/N-Power Supply>
LO1/LO2/LO3/NO
Connection Terminal<L1/L2/L3/N-Power Supply>
GD1, GD3
Connection Terminal<Ground>
CONV.B.
Converter Circuit Board
L1-A1/IN
Connection Terminal<L1-Power Supply>
L1-A2/OU
Connection Terminal<L1-Power Supply>
L2-A2/OU
Connection Terminal<L2-Power Supply>
L3-A2/OU
Connection Terminal<L3-Power Supply>
N-IN
Connection Terminal
CK-OU
Connection Terminal
63HS
63L
63H
LEV-A
TH32
TH7
TH6
TH3 TH4
M
3
1
2
1
4
1
2
2 1
1
3
1
63HS
LEV-A
TH32
TH7/6
TH3
TH4
( WHT )
(WHT)
( RED )
( WHT )
( WHT )
( BLK )
1
3
63L
1
3
RED
(
)
63H
YLW
(
)
CN4
(WHT)
1
2
CN2
( WHT )
1
7
2
7
F3
CNAC
( WHT )
1 2
F4
3
3 4
21S4
P . B .
3
7
1
3
1
CN2
CN7
(WHT)
(WHT)
2
2
CN4
(WHT)
1
2
CN5
2
(RED)
1
X52A
RED
RED
N . F .
CNAC1
(WHT)
1
3
LI1
LI2
U
U
LI3
U
NI
U
U
GD1
SW12
Switch<Address setting: 10s digit >
LED1
LED<Power Supply: DC5V>
LED2
LED<Connection to Outdoor Unit>
LED3
LED<Transmission: Sending>
LED4
LED<Transmission: Receiving>
LED5
LED<Power Supply: DC12V>
NAME
SYMBOL
C.B.
SW1
SW4
SW5
SW6
SW7
SW8
SW9
SWP
CN31
SS
LED1, LED2 LED<Operation Inspection Indicators>
CNM
CNDM
F1~F4
X51,X52,X55 Relay
LEV-C
M
LEV-B
M
3
5
5
*2
*1
6
1
6
1
3
1
5
LEV-B
CNVMNT
CNMNT
(RED)
(WHT)
(WHT)
1
CNM
14
5
WHT
(
)
CN31
1
6
1
LEV-C
BLU
3
(
)
1
5
1
3
1
3
1
21S4
SV2
SS
(GRN)
(BLU)
(WHT)
SV
7
TB-W
+
BLK
MC
W
TB-V
WHT
V
MS
3 ~
U
--
RED
TB-U
+
TB-L3
BLK
TB-L2
WHT
TB-L1
RED
--
+
+
TB-P2
TB-C1
TB-N1
+
+
CB1
CB2
CK
2
CNCT
(RED)
1
2
1
+
+
--
U
1
3
3
1
CNL
CNDC
GD3
(BLU)
(PNK)
2
18
NAME
Controller Circuit Board
Switch<Forced Defrost, Defect History Record
Reset, Refrigerant Address>
Switch<Test Operation>
Switch<Function Switch>
Switch<Model Select>
Switch<Function Setup>
Switch<Function Setup>
Switch
Switch<Pump Down>
Connector<Emergency Operation>
Connector< Connection for Option>
Connector<A-Control Service Inspection Kit>
Connector
< Connection for Option (Contact Input) >
Fuse<T6.3AL250V>
When M-NET adapter is connected
5
SW11
SW1
5
1
LED2
SW12
LED3
LED4
M-NET ADAPTER
2
CND
1
(WHT)
3
1
3
A B S
TB7
M-NET
*1. MODEL SELECT
The black square (■) indicates a switch position.
MODEL
SW6
SW5-6 2
ON
ON
100Y
OFF
OFF
1 2 3 4 5 6 7 8
1 2 3 4 5 6
ON
ON
125Y
OFF
OFF
1 2 3 4 5 6 7 8
1 2 3 4 5 6
*2. SW5 -1 to 5 : Function Switch
3
CONV.B.
3
1
CNAC2
(RED)
3
ACL1
LO1
RED
ACL2
LO2
WHT
ACL3
LO3
BLK
NO
BLU
ACL4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents