Cembre B68M-P18A-KV-RC2 Operation And Maintenance Manual page 17

Electro-hydraulic battery pump, radio controlled

Advertisement

4.4) SS-TCY support strap
The support strap allows the cutting head to hang securely from a suitable support e.g when
cutting wall mounted cable inside manholes.
Connect the strap end hooks to the hanging eyelets (2) of the head (Ref. to Fig. 11).
Securely wrap the strap around a stable support above the head and latch it using the ring
(17).
Set the length of the strap by means of the buckle (16) support the head in a stable position.
5. INSTRUCTIONS FOR USE (Cutting operation)
Cutting operations must be strictly in accordance with the
safety and working procedures established by the respon-
sible power utility.
STEP 1- Checking and testing the pump prior to cutting operations
Check all components (cutting head, flexible insulated hose, couplings and pump) before use to
verify there is no damage or leakage.
Checking and testing the unit prior to any cutting operations:
Check the battery charge and recharge it if necessary following the instructions in the battery
charger user manual. When a cutting operation begins, a check is made to determine whether
the battery charge is sufficient to complete the cutting operation. If this is not the case the
pump does not start. The LED (4) light will FLASH intermittently and the buzzer (5) will emit
an audible signal coordinated with the LED light.
P =
0 bar
Remove the battery from the pump (Ref. to Fig. 6).
1
*
Connect the flexible hose first to the cutting head and then to the pump (Ref. to Fig. 7).
Insert the battery into the pump.
Activate the pump by pressing forward the control button (11) on the pump,
P =
0 psi
2
*
the display lights up and the pump setting is displayed.
Turn on the radio control by pressing the ON/OFF button (1), the LED will
flash green, after 3 minutes the radio control automatically switches off.
Press the pump button (2) on the radio control to perform a test cutting operation.
3
During the operation the pump's LED light will FLASH intermittently and the buzzer will
emit an audible signal coordinated with the LED light.
4
17
RC ON
5
(purchase separately)
RC OFF
P
P
= 729 bar
n
P =
0 bar
P =
P
P
= 10573 psi
n
n
P =
0 psi
P
p
P
= 729 bar
P
n
OK
P =
.... bar
P = 0 bar
P
= 729 bar
n
0 bar
= 729 bar
= 731 bar
= 729 bar
n
OK
= 325 bar
p
B
B