Download Print this page

Toshiba LF810 Product Data Sheet page 5

Stationary ultrasonic flowmeter

Advertisement

4. Specifications
4-1. Overall Specifications
Measurement
Fluids
Temperature range
Turbidity
Pipes
Material
Diameters
Lining
Measurement
Converted to flow velocity: -30 m/s to +30 m/s
range
Number of
1 measurement path
measurement
paths
Measurement
1 s
cycle
Measurement
Performance
1"-1.75"
(DN 25 ~ 40mm)
2" – 3.5"
(DN 50 ~ 90mm)
4" – 10"
(DN 100 ~ 250mm)
12" – 24"
(DN 300 ~ 600mm)
Repeatability
Range ability
Note:
1) For volumetric flow rate.
2) Fully developed and rotationally symmetrical flow profile required.
3) Verified by manufacturer's conditions.
Measurement
method
Ultrasonic pulse transit time difference method
European
compliance
Safety: IEC61010-1 2nd Edition
(CE marking)
EMC: EN61326-1:2006 + EN61326-2-3:2006
4
Homogeneous and ultrasonically conductive fluids
(Clean water, waste water, industrial water, river water, sea
water, pure water, etc.)
-4 to 140°F (-20 to 60°C)
Note:
1) above also applicable to ambient temperature
2) For main unit, 14 to 122°F (-10 to 50°C)
10000 mg/L or less
Note) No air bubbles
Pipes made of materials that allow stable transmission of
ultrasonic waves, such as steel, stainless steel, cast iron,
ductile cast iron, PVC, FRPM, etc.
Note) Applicable pipe bores may vary depending on the pipe material
and condition.
1" – 24" (DN25mm to DN600mm)
None, tar epoxy, mortar, etc.
Note) Linings must be closely adhered to the base pipe.
±2.5%(*) of reading, however ±0.025(*) m/s for flow
velocities less than 1 m/s
(*) Depending on calibration
±2.0% of reading, however ±0.020 m/s for flow velocities
less than 1 m/s
±1.5% of reading, however ±0.015 m/s for flow velocities
less than 1 m/s
±1.0% of reading, however ±0.010 m/s for flow velocities
less than 1 m/s
±0.5%
1 : 300
.

Advertisement