Introduction And Features; How To Use This Document; Chapter 0~2 - ABB UMC22-FBP Technical Description

Fieldbusplug universal motor controller
Table of Contents

Advertisement

Universal Motor Controller UMC22-FBP
Software version 4.0
V 6
Chapter 1.1~1

1. Introduction and features

1.1 How to use this document

A particular motor feeder shall be planned and realized:
Select the dedicated part in this document (examples):
Direct starter see chapter 7.3.3
Reversing starter see chapter 7.3.4
or others
(the chapter number in the header of the pages - third line - shall make it easy to fi nd)
The subchapters of chapter 7. which includes all starter types start with a circuit diagram for the basic
confi guration. On top of the circuit diagram the parameters are named that must be changed, with
numbers of the chapters. Direct starter is one selection example of the parameter Control function.
All other parameters that are not named here can be kept as default values.
The motor feeder shall get additional functions:
The next circuit diagram in chapter 7 shows an example of a circuit diagram with additional functions.
These functions can be selected with parameters named on top of the diagrams.
To fi nd out which other functions can be parameterized it is recommended to study the parameter list
see chapter 4.3.1, particularly the parameters Local control and DI0, DI1, DI2 Multi-function input see
chapters 4.3.4. An examle for the parameterization of the parameter(s) DI0, DI1, DI2 Multi-function
input is shown in chapter 3.4.2.
Find out which steps during planning and commissioning are necessary:
Chapter 3.1 ff. also gives more detailed hints e.g. chapter 3.2.1, chapter 3.2.2, chapter 3.2.4, etc.
The way to integrate the UMC22 into the different types of control systems / DCS is, unfortunately,
not uniform.
Chapter 3.3.3 gives hints based on the AC31 CPU 07KT98 that can help to understand.
The integration into higher sophisticated control systems is supported by additional medias e.g.
Device Type Manager (DTM) and others. Please ask for appropriate documentation.
The motor can be started and stopped on different ways including emergency start
see chapter 3.4.1.
Signalling on the UMC22 see chapter 3.7.1, on the Panel see chapter 3.7.2 and 8., in the telegram
see chapters 4.2.1
Use of the Control Panel, introduction, particular the two modes see chapter 3.7.2, details see
chapter 8.
If any fault appears see chapter 3.7.4, particular for the Control Panel see chapter 8.2.
Remark: The diagnosis telegram shown in the motor feeder chapters, e.g. chapter 7.3.3, shows also
the info displayed by the Control Panel. Example: F003 = Communication fault.
Build a bus confi guration:
Consult the appropriate FBP document, e.g. PDP21, PDP22 (PROFIBUS)... .
Bus confi gurations with FBP devices only are easy to realize with low possibilities to make a fault.
Confi gurations with mixed FBP devices and others need more attentiveness.
A fault appears:
Consult chapter 3.7.4, as a fi rst overview the table shows the info in the diagnosis telegram and on the
Control Panel.
FieldBusPlug / Issue: 02.2008
- 5 -
UMC22-FBP

Hide quick links:

Advertisement

Table of Contents
loading