ControlNet Network Channel Status Indicators

The ControlNet network channel status indicators appear in one of the
following states:
• Steady - indicator is on continuously in the defined state.
• Alternating - the two indicators alternate between the two defined
states at the same time (applies to both indicators viewed together).
The two indicators are always in opposite states, out of phase.
• Flashing - the indicator alternates between the two defined states
(applies to each indicator viewed independent of the other). If both
indicators are flashing, they must flash together, in phase.
The ControlNet Network Channel Status Indicators table summarizes the
meanings of these states.
ControlNet Network Channel Status Indicators
and
A
B
Off
Steady red
Alternating
red/green
Alternating red/off Incorrect node configuration
or
A
B
Off
Steady green
Flashing green/off Temporary errors
Publication
1756-IN604A-EN-P - February 2006
Cause
No power
Faulted unit
Self-test
Cause
Channel disabled
Normal operation
Action
None or power up.
Cycle power or reset unit.
If fault persists, contact A-B
representative or distributor.
None
Check network address and other
ControlNet network configuration
parameters.
Action
Program network for redundant
media, if required.
None
None; unit will self-correct.