Bryant 582A Installation, Start-Up, And Operating Instructions Manual page 3

Single packaged gas heating/ electric cooling units
Table of Contents

Advertisement

REQUIRED CLEARANCE TO COMBUSTIBLE MATL.
TOP OF UNIT...................................................................................14.00 [355.6]
DUCT SIDE OF UNIT.........................................................................2.00 [50.8]
SIDE OPPOSITE DUCTS ................................................................14.00 [355.6]
BOTTOM OF UNIT .............................................................................0.50 [12.7]
ELECTRIC HEAT PANEL .................................................................36.00 [914.4]
NEC. REQUIRED CLEARANCES.
BETWEEN UNITS, POWER ENTRY SIDE ....................................42.00 [1066.8]
UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE .36.00 [914.0]
UNIT AND BLOCK OR CONCRETE WALLS AND OTHER
GROUNDED SURFACES, POWER ENTRY SIDE.........................42.00 [1066.8]
LEGEND
CG - Center of Gravity
COND - Condensor
EVAP - Evaporator
NEC - National Electrical Code
REQ'D - Required
NOTE: Dimensions are in in. [mm]
UNIT
ELECTRICAL CHARACTERISTICS
582A018040
582A024040/060
582A030040/060
208/230-1-60, 208/230-3-60
582A036060/090
208/230-1-60, 208/230-3-60, 460-3-60
582A042060/090
208/230-1-60, 208/230-3-60, 460-3-60
583A024040/060
583A030040/060
208/230-1-60, 208/230-3-60
583A036060/090
208/230-1-60, 208/230-3-60, 460-3-60
INCHES [mm]
INCHES [mm]
UNIT WEIGHT
lb
208/230-1-60
249.0
208/230-1-60
280.0
280.0
320.0
355.0
208/230-1-60
290.0
313.0
321.0
Fig. 2—582A018-042 and 583A024-036 Unit Dimensions
REQUIRED CLEARANCE FOR OPERATION AND SERVICING
EVAP. COIL ACCESS SIDE............................................................36.00 [914.0]
POWER ENTRY SIDE....................................................................36.00 [914.0]
(EXCEPT FOR NEC REQUIREMENTS)
UNIT TOP .......................................................................................48.00 [1219.2]
SIDE OPPOSITE DUCTS ..............................................................36.00 [914.0]
DUCT PANEL .................................................................................12.00 [304.8] *
*MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN 12.00 [304.8] FROM
WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE.
UNIT HEIGHT IN. (MM)
"A"
kg
113.2
35.02 (889.5)
127.3
35.02 (889.5)
127.3
35.02 (889.5)
145.1
37.02 (940.3)
161.4
35.02 (889.5)
131.5
35.02 (889.5)
142.0
39.02 (991.1)
145.6
35.02 (889.5)
—3—
INCHES [mm]
CENTER OF GRAVITY
IN. (MM)
X
Y
20.0 (508.0)
14.0 (355.6)
15.0 (381.0)
22.5 (571.5)
13.0 (330.2)
15.0 (381.0)
21.5 (546.1)
13.75 (349.3)
15.0 (381.0)
22.5 (571.5)
14.0 (355.6)
13.0 (330.2)
21.5 (546.1)
13.5 (342.9)
13.0 (330.2)
22.0 (558.8)
14.5 (368.3)
16.0 (406.4)
22.0 (558.8)
15.3 (387.4)
17.6 (447.0)
22.0 (558.8)
15.3 (387.4)
16.5 (419.1)
C00055
Z