Bryant 582A Installation, Start-Up, And Operating Instructions Manual page 18

Single packaged gas heating/ electric cooling units
Table of Contents

Advertisement

FIELD
W54 BLK
SUPPLY
W55 YEL
POWER
EQUIP_GND
COOLING FAN LOGIC
T
0
T+30
G
G
ENERGIZED
DE-ENERGIZED
HEATING FAN LOGIC
0
45
T
T+30
W
BR
W
BR
ENERGIZED
DE-ENERGIZED
RC
24V SPLICE BOX
RH
OFF
HEAT
B
AUTO
COOL
AHA
THI
WI
OFF
HEAT
AUTO
YI
TCI
COOL
AUTO
G
FAN
SW
ON
FIELD-THERMOSTAT
COMMON
UNIT COMPONENT ARRANGEMENT
OUTDOOR FAN
OFM
SECTION
COMPRESSOR
CONTROL BOX
INDOOR FAN
SECTION
LS
SECTION
TRAN
FROM COMP
CAP 1
IGC
IFM
CAP 2
QT
0
COMP
IDM
MGV
C
1 2
S
R
1
GAS SECTION
Fig. 17—460-3-60 Wiring Diagram, Units 582A and 583A
C
11
21
1
23
13
1
W15 YEL
PRIMARY
460V
W14 BLK
COM
TRAN1
SECONDARY
24V
24V
CR
W13 BLK
L1
BR
W39 RED
IGC
W19 WHT
W20 GRN
W21 RED
CR
FAN
BR
LOGIC
SAFETY
GVR
LOGIC
HV
TRAN
1 2 3
AHA
– Adjustable Heat
Anticipator
BR
– Blower Relay
C
– Contactor
CAP
– Capacitor
EQUIP
COMP – Compressor Motor
GND
CR
– Combustion Relay
CS
– Centrifugal Switch
EQUIP – Equipment
21
11
FS
– Flame Sensor
C
23
13
FU
– Fuse
GND
– Ground
GV
– Gas Valve
CAP3
GVR
– Gas Valve Relay
HS
– Hall Effect Sensor
HV
– High Voltage
TRAN – Transformer
I
– Ignitor
24V
IDM
– Induced-Draft Motor
SPLICE BOX
IFC
– Indoor-Fan Contactor
IFM
– Indoor-Fan Motor
HS
IGC
– Integrated Gas Unit
Controller
L1
– Line
LS
– Limit Switch
LS1
– Limit Switch
MGV
– Main Gas Valve
FS
RS
NOTES:
1. If any of the original wires furnished are replaced, they must be
DISCONNECT
replaced with type 90 degree C wire or its equivalent.
PER NEC
2. See price pages for thermostat and subbases.
3. Use 75 degree C copper conductors for field installation.
4. For high speed IFM, disconnect RED wire from IGC terminal BM
and connect BLK wire from IFM. For medium speed, disconnect
RED wire from IGC terminal BM and connect BLU wire from IFM.
5. Models 4BGX024-036 have LS1 and LS2 wired in series. Models
48GX042-060 have LS1 only.
—18—
W43 BLK
CAP 2
W6 YEL
QT
W8 BLK
W7 YEL
(060 ONLY)
W56 BLU
(SEE NOTE #4)
W61 YEL
W63 YEL
W64 YEL
CAP 1
QT
460
CAP 3
QT
C
CM
BM
L2
L2
J2
L2
IFC
W
G
5 AMP
R
FU
RT
BLU
RS
RS
RS
BLU
1
3
LS
V10
LSI
LS
V10
1
3
CS
GVR
YEL
CS
W35 GRA
GV
W34 BRN
FLAME SEN
GV
YEL
FS
BRN
W41 GRN-YEL
C
W32 BRN
C
W46 BRN
HS
GROUNDED
TRU STANDOFF
W33 YEL
LEGEND
NEC
– National Electrical
OFM
– Outdoor-Fan Motor
QT
– Quadruple Terminal
RS
– Rollout Switch
SEN
– Sensor
SW
– Switch
TRAN – Transformer
BLK
OFM
YEL
BRN
L1
C
L2
R
COMP
L3
S
YEL
RED
YEL
IFM
BRN
V10
YEL
IDM
BRN
GRN-YEL
W46 BRN
MGV
1
2
GRN-YEL
C_
C1
C2
W32 BRN
W30 BRN
W30 BRN
Code
Field Splice
Terminal (Marked)
Terminal (Unmarked)
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or
Optional Wiring
To Indicate Common
Potential Only, Not
to Represent Wiring
C00059