Owner's Manual — Phoenix D850
The Phoenix D850 provides the perfect blend of portability,
versatility, and performance the restoration industry has
been seeking in a medium-capacity desiccant dehumidifier.
It combines the wide operating range and ultra-low grains
of the Phoenix 1200 with the portability of an LGR like our
Phoenix 250 Max. The included remote humidistat and
process blower speed control allow you to tailor the drying to
the task at hand.
The D850 delivers 850 CFM of ultra-low grain process air and
removes a stunning 370 pints per day at AHAM conditions.
The true four-hole design* allows for positive, neutral, or
negative pressurization of the affected area. Three-hole
desiccants** inherently pull unaffected and/or outside air
into the drying chamber.
The D850 allows you to connect a remote humidistat
(included), thermostat, or other low-voltage control allow
you to achieve precise conditions anywhere within the
affected area. When the job calls for even deeper drying, the
process blower speed control reduces the process airflow for
maximum grain depression.
The Phoenix D850 Desiccant Dehumidifier
• 370 pints per day @
AHAM (80°F, 60%RH)
• 850 CFM process airflow
• Wide operating range
• Operates vertically or
horizontally
• True four-hole
configuration
• High or low power
(50A or 30A)
• Two 8' Power Cords
(1 dryer, 1 range) included
with unit
Specifications subject to change without notice.
Toll-Free 1-800-533-7533
4201 Lien Rd • Madison, WI 53704
Installation, Operation & Service Instructions
Read and Save These Instructions
• Power cords can be stored
on-board
• Remote humidistat (with
25' connecting cable)
included with unit
• Multiple ducting options
• Rugged stainless steel
cabinet
The D850 operates vertically or horizontally and will fit inside
most crawlspaces. The lower carrying handle makes moving
the unit into and out of the crawlspace a breeze. Having the
D850 securely inside the crawlspace deters the possibility of
tampering with the dehumidifier or the setup. The 850 CFM
process air stream will provide 3 ACH on an affected area up
to 16,000 cubic feet.
The Phoenix D850 is easy to transport and set up. It will fit
on your truck in the areas designed for your LGRs and will
move around the jobsite with the same portability. Stairs
are a snap thanks to the lower carrying handle. Power to the
unit is provided by either a 30- or 50-amp 230-volt grounded
power cord (both are included). Stow the cords in the on-
board storage compartment for transport. The reactivation
air stream is ducted through 6" flex duct provided with the
unit.
*Having completely separate process and regeneration airstreams.
**Where regeneration airstream is pulled from the process airstream.
Phoenix D850
PN 4034000
Patent Pending
1
www.UsePhoenix.com • sales@UsePhoenix.com
TS-799
05/17 Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Phoenix D850 and is the answer not in the manual?

Questions and answers

Summary of Contents for Therma-Stor Phoenix D850

  • Page 1: Introduction

    16,000 cubic feet. the task at hand. The Phoenix D850 is easy to transport and set up. It will fit The D850 delivers 850 CFM of ultra-low grain process air and on your truck in the areas designed for your LGRs and will removes a stunning 370 pints per day at AHAM conditions.
  • Page 2: Table Of Contents

    • Extreme caution is necessary when device is used by 3. Operation ................3 or near children and whenever device is left operating 3.1 How the Phoenix D850 Works ........3 unattended. 3.2 Avoiding Secondary Damages ........3 • Always unplug unit when not in use.
  • Page 3: Operation

    3.1 How the Phoenix D850 works Take care to prevent the reactivation exhaust air stream Your Phoenix D850 uses two separate air streams – Process from causing secondary damage due to condensation. (Fig. 1) and Reactivation (Fig. 2). Moisture is transferred from the incoming process air to the outgoing reactivation air.
  • Page 4: Transporting

    Consider using an external humidistat and/or thermostat • Maintain a minimum of 36” clearance around the D850 (see Section 3.8.5) to control the conditions in the affected DO NOT use the Phoenix D850 as a bench or table. • area. 3.6 Ducting Connections 3.3 Transporting...
  • Page 5: Ducting Options

    3.8.1 POWER SETTING Switch 3.7 Ducting Options This switch selects either high or low power operation. The Phoenix D850 can be ducted as shown in Figures 3, 4, 3.8.2 CONTROL MODE Switch and 5 to create negative, neutral, or positive pressure in the The CONTROL MODE switch can be used to turn the unit affected area.
  • Page 6: Balance Knob

    Step 1: Depress button (1A) and twist reactivation outlet 4.1 Air Filter Replacement duct collar (1B) 15° counter-clockwise to remove. The Phoenix D850 is equipped with two air filters that must Step 2: Unplug rotor drive motor wire connector (not shown). be checked regularly.
  • Page 7: Seals

    4. On Always On mode or if the external control contacts are closed on External Control mode, the “Regen Air OK” CAUTION: Servicing the Phoenix D850 with its high voltage light illuminates once there is sufficient airflow through circuitry presents a health hazard which could result in heaters.
  • Page 8: Troubleshooting

    5.3 Troubleshooting Blowers and rotor motor running REGEN AIR OK lamp illuminates, but no other lamps illuminate. No heat. • A 50A circuit is required to use the High Power setting. 1. High process inlet or regen inlet temperature limit Connecting the D850 to a 30A circuit with the power reached (120°F) setting switch set to High will eventually cause the...
  • Page 9: Wiring Diagram

    6 Wiring Diagram Wiring Schematic and Ladder Diagram POWER INLET * DENOTES POSITION NUMBER IN 9-PIN 9 PIN WIRING 2 PIN 208-240 VAC, 1PH 50/60HZ CONNECTOR THROUGH LOWER PANEL MATE-N-LOK BLOCK MATE-N-LOK ROTOR MOTOR PROC 4 PIN BLWR MATE-N-LOK 4µF REGEN BLWR BLOWER...
  • Page 10: Service Parts List

    7 Service Parts List Item Part No. Description Item Part No. Description 4036842 PRESSURE SWITCH 4036541 PROCESS BLOWER 4036118 THERMAL OVERLOAD, PROCESS INLET 4036841 SPEED CONTROL, PROCESS IMPELLER 4022636 AIR FILTER, PROCESS 4036123 MOTOR KIT, DESICCANT WHEEL 4027330 ROCKER SWITCH, HIGH/LOW 4026784 DUCT COLLAR, 6”...
  • Page 11: Warranty

    (but all warranty periods will be extended by the period of time, if any, that the Phoenix D850 Dehumidifier is out of service while awaiting covered warranty service).

Table of Contents