3.1 SPECIFICATIONS
Model Series
20/12 500 CFM
20/12 630 CFM
20/12 750 CFM
20/12 800 CFM
20/12 960 CFM
COMPRESSOR:
Type
Maximum Full Load Operating Pressure
Bearing Type
Cooling
Lubricant
Sump Capacity
Control
MOTOR:
Type
Size
Speed

3.2 LUBRICATION GUIDE

Sullair standard compressors are filled with Sullube
32 fluid as factory fill. MIXING OF OTHER FLUIDS
WITHIN THE COMPRESSOR WILL VOID ALL
WARRANTIES.
Sullube 32 fluid should be changed every 1800
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
DIMENSIONS WITHOUT ENCLOSURE
Length
Width
in
mm
in
143.5
64
3645
143.5
64
3645
143.5
64
3645
186
82
4724
186
82
4724
2--Stage Oil Flooded Rotary
350 PSIG (2413kPa)
Anti--Friction
Pressurized Compressor Fluid
Sullube 32
35 U.S. Gallons (132 Liters)
Electro--Pneumatic
O.D.P., 460V, A.C., Three Phase, 60 Cycles
See Model Series above.
1200 RPM and 1800 RPM
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
Maintenance of all other components is still recom-
mended as indicated in the Operator's manual.
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in this manual. Contact your Sullair Repre-
sentative for details.
Section 3
SPECIFICATIONS
Height
mm
in
mm
71.5
1626
1816
71.5
1626
1816
71.5
1626
1816
80.5
2083
2045
80.5
2083
2045
Weight
lb
kg
6000
2722
6000
2722
6000
2722
9400
4264
9600
4354
13