FLUE OPTIONS

CAUTION: Non accessible flue systems:
▶ Where a flue system is not going to be accessible,
provision must be made for service and inspection.
▶ Voids containing concealed flues must have at least
one inspection hatch no less than 300mm square.
▶ Flue joints within the void must not be more than 1.5
metres from the edge of the inspection hatch.
▶ Inspection hatches should be located at changes of
direction.
▶ If this is not possible, bends should be viewable from
both directions.
NOTICE: Effective flue lengths:
▶ each 90° bend used is equivalent to
2 metres of straight flue
▶ each 45° bend used is equivalent to
1 metre of straight flue
Plume management kits are available for the 60/100
horizontal flue system.
Refer to the manual supplied with the plume
management kits for complete installation instructions
FLUE LENGTHS
The flue systems have different maximum flue lengths
The Greenstar series has the option of two horizontal 60/100 RSF
(telescopic and longer telescopic) and one horizontal 80/125 RSF
(telescopic) flue system and two vertical RSF (60/100 or 80/125) flue
systems:
The next page shows various fluing options.
Refer to the Flue options in table 15 for the straight flue lengths required
to achieve the maximum flue length.
i System boilers
FLUE TYPE
1
Telescopic horizontal flue assembly
Longer telescopic horizontal flue assembly
2
Horizontal flue extension
3
Horizontal flue with 1 x 90° bend
4
Horizontal flue with 2 x 90° bends
5
High level horizontal flue
6
High level horizontal flue with 2 x 90° bends 2,600 11,000
7
High level horizontal flue with 3 x 90° bends N/A
8
Vertical balanced flue assembly
9
Vertical balanced flue with 2 x 90° bends
10 Vertical balanced flue with 2 x 45° bends
Table 15 Flue options
Part number
Flue
7 716 191 082
60/100
7 716 191 171
60/100
7 719 003 702
80/125
7 719 002 430
60/100
7 719 002 431
80/125
Table 16 Flue option part numbers
Maximum total
flue length (mm)
60/
80/125
100
570
1,070
790
N/A
4,600 13,000
2,600 11,000
N/A
9,000
4,600 13,000
9,000
6,400 15,000
2,400 11,000
4,400 13,000
Description
Telescopic horizontal flue assembly
Longer telescopic horizontal flue
assembly
Telescopic horizontal flue assembly
Vertical flue assembly
Vertical flue assembly
6 720 804 532 (2012/09)