Pre-Installation
4.4

Flue systems considerations

WARNING:
Flue systems
Possible flue gas escape
▶ Use Worcester, Bosch Group approved Condensfit II flue systems
only, no other manufacturer's flue have been tested or approved for
use with Worcester, Bosch Group appliances.
CAUTION:
Concealed flue systems:
▶ Where a flue system is going to be concealed, provision must be
made for service and inspection.
▶ Voids containing concealed flues must have at least one inspection
hatch no less than 300mm square.
▶ Flue joints within the void must not be more than 1.5 metres from the
edge of the inspection hatch.
▶ Inspection hatches should be located at changes of direction.
▶ If this is not possible, bends should be viewable from both directions.
Refer to the manual supplied with the Worcester, Bosch Group flue kit for
complete installation instructions.
Flue kit part numbers
Part number
Flue Ø
Description
7 738 112 869 60/100
Telescopic horizontal flue kit (Silver)
7 716 191 082 60/100
Telescopic horizontal flue kit
7 716 191 171 60/100
Extended telescopic horizontal flue kit
7 733 600 048 60/100
Horizontal high level telescopic flue kit
7 719 003 702 80/125
Telescopic horizontal flue kit
7 719 002 430 60/100
Vertical balanced flue kit
7 719 002 431 80/125
Vertical balance flue kit
Table 8 Flue kit assembly part numbers
4.4.1

Flue length

The maximum flue length will depend on the following factors:
• 60/100mm flue system
– Vertical/horizontal flue type
– Appliance output
– Plume management length
• 80/125mm flue system
– Vertical/horizontal flue type
– Appliance output
16
Horizontal maximum flue lengths
Flue length [L]
60/100
Output No plume
+ 500mm
management
of plume
management
50 kW
9,000mm
9,000mm
45 kW
8,000mm
8,000mm
40 kW
11,000mm
11,000mm
35 kW
10,000mm
10,000mm
30 kW
17,000mm
17,000mm
Table 9 Maximum flue lengths - Horizontal flues
Vertical maximum flue lengths
Flue length [L]
Output
60/100
50 kW
12,000mm
45 kW
12,000mm
40 kW
15,000mm
35 kW
14,000mm
30 kW
21,000mm
Table 10 Maximum flue lengths - Vertical flues
Flue system bends
NOTICE:
Effective flue lengths of bends:
Each bend used has an equivalent straight flue length.
▶ Refer to the table below.
Effective flue length
Bend
60/100
45°
0.5m
90°
1.5m
Table 11 Effective length of bends
4.4.2

Flue options

The systems have diiferent maximum flue lengths, refer to the following
example flue options for those maximum flue lengths.
Horizontal high level flue assembly
Fig. 15 Horizontal flue option
• Flue length [L] (initial bend included in length calculation)
– 60/100 = 202 - 603mm
– 80/125 = N/A
Greenstar 8000 Life – 6720883866 (2019/04)
Flue length
[L]
80/125
+ 4500mm of
No plume
plume
management
management
available
6,200mm
40,000mm
5,200mm
35,000mm
8,200mm
35,000mm
7,200mm
29,000mm
14,200mm
25,000mm
Flue length [L]
80/125
40,000mm
35,000mm
35,000mm
29,000mm
25,000mm
80/125
0.5m
1.5m
60/100 mm
383 mm - 603 mm
130 mm Min