FLUE OPTIONS

The Greenstar series has the option of two horizontal RSF (60/100 telescopic and
80/125) flue systems and two vertical RSF (60/100 or 80/125) flue systems:
The systems have different maximum flue lengths
This page shows various fluing options with the straight flue lengths required to
achieve the maximum flue length. Note that:
each 90° bend used is equivalent to 2 metres of straight flue
each 45° bend used is equivalent to 1 metre of straight flue
NOTE: Plume management kits are available for the 60/100 horizontal flue option.
Refer to the manual supplied with the Plume management kits for complete
installation instructions
Telescopic horizontal flue assembly
Horizontal flue extension
High level horizontal flue
Horizontal flue with 2x90° bends
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR Ri
8 716 115 168a (06/2008)
Maximum telescopic flue length
100mmØ
125mmØ
12 Ri
570mm
1,070mm
15 Ri
570mm
1,070mm
18 Ri
570mm
1,070mm
24 Ri
570mm
1,070mm
Maximum total flue length
100mmØ
125mmØ
12 Ri
4,600mm 13,000mm
15 Ri
4,600mm 13,000mm
18 Ri
4,600mm 13,000mm
24 Ri
4,600mm 13,000mm
Maximum total flue length
100mmØ
125mmØ
12 Ri
4,600mm 13,000mm
15 Ri
4,600mm 13,000mm
18 Ri
4,600mm 13,000mm
24 Ri
4,600mm 13,000mm
Maximum total flue length
100mmØ
125mmØ
12 Ri
2,600mm 11,000mm
15 Ri
2,600mm 11,000mm
18 Ri
2,600mm 11,000mm
24 Ri
2,600mm 11,000mm
High level horizontal flue with 2x90° bends
Maximum total flue length
100mmØ
12 Ri
2,600mm 11,000mm
15 Ri
2,600mm 11,000mm
18 Ri
2,600mm 11,000mm
24 Ri
2,600mm 11,000mm
High level horizontal flue with 3x90° bends
Maximum total flue length
100mm‚Ø
12 Ri
N/A
15 Ri
N/A
18 Ri
N/A
24 Ri
N/A
Vertical balanced flue assembly
Maximum total flue length
100mmØ
12 Ri
6,400mm 15,000mm
15 Ri
6,400mm 15,000mm
18 Ri
6,400mm 15,000mm
24 Ri
6,400mm 15,000mm
Vertical balanced flue system with 2x45° bends
Maximum total flue length
100mm‚Ø
12 Ri
4,400mm 13,000mm
15 Ri
4,400mm 13,000mm
18 Ri
4,400mm 13,000mm
24 Ri
4,400mm 13,000mm
Vertical balanced flue with 2x90° bends
Maximum total flue length
100mmØ
12 Ri
2,400mm 11,000mm
15 Ri
2,400mm 11,000mm
18 Ri
2,400mm 11,000mm
24 Ri
2,400mm 11,000mm
FLUE OPTIONS
125mmØ
125mmØ
9,000mm
9,000mm
9,000mm
9,000mm
125mmØ
125mmØ
125mmØ
13