MOl 890 DIAGNOSTIC SECTIONS
MOl 890 allows you to select the same routines as used in
the other MOls. In other words, routine PT03 in MOl
890 is the same as PT03 in MOl 800. However, the
routines in MOl 890 do not halt or branch when sensing
a failing condition. The main advantage of MOl 890 is
that it allows you to select individual MOl sections which
is especially useful when scoping intermittent failures.
Enter
l
~
MOl 890 Diagnostic Section
Provides selection of routines for I/O
devices.
~
~
891
-
Tap'e write routines. These are the same
routines as MOls 840, 841,843,844,
845,846, and 847.
892 - 5103 J>rinter routines. These are the same
routines as MOl 800,801,802,803,804,
and 805.
893 - Tape read routines. These are the same
routines as MOl 860 and 861.
894 - Communications/Serial I/O routines. These
are the same routines as those in MOl 820.
Intermittent Failures Troubleshooting Guide